LED and Beeper Indications

The Base Station LED indicators and the scanner’s LEDs and beeper are used to announce system status and perform other useful signals. The tables below list the default function of each of the various indica- tors.

 

 

Some LED and beeper indications can be disabled

 

 

or modified via scanner programming. The tables

 

 

indicate the default behavior of the indicators, with

NOTE

 

shaded rows representing features that are pro-

 

grammable.

 

 

Table 1. Scanner GREEN LED Functions

LED

 

DURATION

COMMENT

INDICATION

 

 

Disable

 

100ms on, 900 ms off

Indicates the scanner has

Indication

 

 

been disabled.

Good Read

 

500 ms on

Indicates a bar code has

Indication

 

 

been read and decoded.

Program Mode

 

500 ms on, 500 ms off

Indicates the scanner is in

 

Continuous flashing

Indication

 

Programming Mode.

 

 

Field Replace-

 

Varies. Consists of a long flash

Enables service techni-

 

followed by multiple short

 

cians to identify Field

able Unit (FRU)

 

flashes.

 

Replaceable Unit (FRU)

Indications

 

 

 

 

errors.

 

 

 

 

 

Two flashes at 100 ms on, 350

Occurs at trigger pull before

Low Battery

 

ms off.

the laser is enabled. Indi-

Indication

 

 

cates the battery is in need

 

 

 

of recharging.