TURBOPOWER®

OIL

PACKAGED WATER HEATER

 

 

 

 

 

 

POLYSHIELD® POLYMER-LINED STORAGE TANK

 

 

 

 

 

 

 

 

 

TANK SERIES 600 GALLONS

 

 

 

 

 

 

 

 

 

 

Recovery gph

 

 

 

 

 

Dimensions (inches)

 

 

Blower

Shipping

 

Model

Input

 

Gph

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

Number

 

 

 

Btu/h

 

#2 Oil

 

 

 

 

 

 

 

 

 

 

Volt/Ph/

40°- 120°F

40°- 140°F

 

 

A

 

B

J

 

K

HP

 

lbs

 

 

 

 

 

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

P 600A-TPO

250

200

 

199,000

 

1.4

 

28

 

4

17

 

41

1/3

 

115/1/8

2270

500

P 600A-TPO

500

400

 

399,000

 

2.8

 

28

 

5

17

 

41

1/2

 

115/1/10

2290

750

P 600A-TPO

750

600

 

600,000

 

4.3

 

31

 

6

17

 

41

1/2

 

115/1/10

2370

1000

P 600A-TPO

1000

800

 

800,000

 

5.7

 

31

 

8

17

 

41

1/2

 

115/1/10

2410

1250

P 600A-TPO

1250

1000

 

1,000,000

 

7.2

 

39

 

8

17

 

41

1/2

 

115/1/10

2650

1500

P 600A-TPO

1500

1200

 

1,200,000

 

8.6

 

39

 

8

17

 

41

1/2

 

115/1/10

2660

2000

P 600A-TPO

2000

1600

 

1,600,000

 

11.4

 

51

 

10

25

 

41

1-1/2

 

115/1/20

3100

2500

P 600A-TPO

2500

2000

 

2,000,000

 

14.3

 

51

 

10

25

 

41

1-1/2

 

115/1/20

3120

3000

P 600A-TPO

3000

2400

 

2,400,000

 

17.1

 

53

 

12

25

 

51

1-1/2

 

115/1/20

3130

3500

P 600A-TPO

3500

2800

 

2,800,000

 

20.0

 

53

 

12

25

 

51

5

 

230/3/16

3160

4000

P 600A-TPO

4000

3200

 

3,200,000

 

22.8

 

53

 

12

25

 

51

5

 

230/3/16

3210

Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss. "J" dimension is for the burner housing only.

Dimensions are in inches unless otherwise specified. For standard and optional equipment, see form PV 6006.

VENTING REQUIREMENTS

-.02" TO -.06" W.C. (NEGATIVE PRESSURE)

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.

FOR PROPER SIZING, CONSULT VENTING SUPPLIER.

* REAR ACCESS MODULE

MODEL PREFIX

M

L

STD or OPTIONAL

 

 

 

 

250-1500

23"

8"

OPTIONAL

 

 

 

 

2000-2500

23"

16"

STANDARD

 

 

 

 

3000-4000

30"

18"

STANDARD

 

 

 

 

STANDARD ELECTRICAL REQUIREMENTS

CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.

MOTOR VOLTAGE:

208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN OPTIONAL CONTROL CIRCUIT TRANSFORMER.

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND SPECIFICATION WITHOUT NOTICE.

PVI INDUSTRIES, LLC

FORT WORTH, TEXAS 76111

PV 5440 04/05

(800) 784-8326 (817) 335-9531 www.pvi.com

Product is patented in the U.S., Canada, and Mexico.

 

 

Page 1
Image 1
PVI Industries 250N600A-TPO dimensions Turbopower OIL, Packaged Water Heater, Venting Requirements, Rear Access Module