PYLE Audio C6110 instruction manual Know Your Air Compressor Description of Operation

Models: C6110

1 22
Download 22 pages 22.14 Kb
Page 11
Image 11

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

Description of Operation

Become familiar with these controls before operating the unit.

On/Auto/Off Switch: Turn this switch "On/Auto" to provide automatic power to the pressure switch and "Off" to remove power at the end of each use.

Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.

On/Auto/Off Switch

Tank

Outlet

Pressure

Pressure

Gauge

Gauge

 

Safety Valve: If the pressure switch

 

 

 

Universal

 

 

 

Quick-

does not shut off the air compressor

Pressure

Safety

 

 

Connect

 

Regulator

at its "cut-out" pressure setting, the

Switch

Valve

Body

safety valve will protect against high

 

 

 

 

 

 

 

 

pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.

Universal Quick-Connect Body: The universal quick-connect body accepts

the three most popular styles of quick-connect plugs: Industrial, automotive (Tru-flate), and ARO. One hand push-to-connect operation makes connections simple and easy.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this

cooling system is an engineered fan. It is perfectly normal

for this fan to blow air through the vent holes in large amounts. You know the cooling system is working when air is being expelled.

Drain Valve

that

11- ENG

A10244

Page 11
Image 11
PYLE Audio C6110 instruction manual Know Your Air Compressor Description of Operation