Terminal Block Connector

The terminal block connector requires the following assembly.

1.Strip the wires to 7 ~ 8 mm.

2.Insert the wires into the male part of the connector according to the Mode you are using. See below.

3.Use a flat-tip screwdriver to secure the wires. Tighten the screws to 6 in.-lbs.

4.Insert the plug into the receptacle on the amplifier.

5.Use a flat-tip screwdriver to secure the connector. Tighten the screws to 6 in.-lbs.

Stereo and Parallel Mode: Wire as shown by loudspeaker symbols 1 and 2, and the solid wires in (Figure 30).

Bridge Mode: Wire as shown by Bridge Mono loudspeaker symbol, and the dashed wires in (Figure 30).

– Figure 30 –

Terminal Block Connector Wiring

 

UL

IEC

Wire range

 

-

6 mm2

 

 

 

 

Solid wire (AWG)

 

28 – 10

-

 

 

 

 

Stranded wire (AWG/mm2 )

 

28 – 10

-

 

 

 

 

Torque (lb.-in.)

 

6

-

 

 

 

 

Wire strip length

 

7 – 8 mm

-

 

 

 

 

– Table 3 –

 

 