Quantum LC - 5500, LCS-4500, LC-7500 How To Operate, Understanding How Your Unit Works, Page

Models: LCS-4500 LC-7500 LC-15000 LC - 5500 LCS-2500 LCS-3500 LC-10000

1 4
Download 4 pages 397 b
Page 4
Image 4
control panel for light commercial with sensor

control panel for light commercial with sensor

Light Commercial air treatment system

with puri-

Contaminant Status

Contaminant Level

 

Contaminant Neutralize

High

Medium

Low

Contaminant Present

 

 

5

 

 

ON

 

10

1

 

 

OFF

03 Active

 

 

 

 

 

MANUAL

AUTO

UNDERSTANDING HOW YOUR UNIT WORKS

1.Contaminant Neutralized: This Green Light indicates that the contaminants are neutralized and the sensor is in standby mode.

In this mode, the fan will run continuously and the unit will monitor the levels of impurities in the air. When the air contains very little or no contaminant the light remains on. NOTE: when the unit is first turned on, this light will blink on and off for about 3 minutes as the unit warms up.

It will remain ON when the unit is ready to operate.

2.Contaminant Present: This Red Light indicates the presence of sufficient impurities in the air to signal the system to begin the cleaning process.

3.O3 Active: This Green Light will turn ON whenever ozone is generated.

4.Contaminant Levels: These Yellow Lights indicate the levels of impurities as HIGH, MEDIUM & LOW. When the purification process is complete, all Yellow Lights will turn off.

5.ON/OFF Control Knob: This Knob must be in the ON position to operate the unit in either mode.

6.Auto/Manual Control Knob: You have a choice of one of two modes.

Auto Mode: In this mode, the unit will operate under the control of the

puri-stat. The air quality will be monitored and treated by the unit automatically.

Manual Mode: In this mode, the unit will by-pass the sensor

circuit and allows the user to operate the unit manually. By turning this

knob clockwise, the fan speed is decreased.

NOTE: On this mode the unit will generate ozone continuously.

Page -4-

control panel for light commercial with out sensor

Light Commercial air treatment system

03 Active

5

6

7

 

8

4

 

 

 

 

 

9

 

 

 

 

 

3

 

 

1

 

 

 

 

POWER ON

2

 

0

 

 

 

 

1

 

 

 

 

ON

 

 

OFF

UNDERSTANDING HOW YOUR UNIT WORKS

1.On / Off knob: Turning the knob clockwise to the ON position will turn

the machine on. Turning this knob clockwise will also control the fan speed. A higher speed will produce more Ozone.

2.O3 Active: This green light will turn ON to indicate that Ozone is generated.

3.Power On: This Red light will remain on when the machine is operating Ozone

HOW TO OPERATE

1.Place your air purifier at counter height or higher. This placement will give you the best possible results. This is an electrical device. To reduce the risk of electric shock, never plug the air purifier into an outlet while your hands are wet. Never expose to rain or place the unit in standing water.

2.Plug the AC power cord to an 110Vac or 240Vac outlet.

3.Place unit at least 3" to 6" from a wall or bulkhead, this allows for proper ventilation.

4.Chose Auto or Manual Mode

5.Turn the unit ON by turning the ON/OFF Control Knob to the ON position. NOTE: If Manual mode is selected, then fan speed control will be available.

Page -5-

Page 4
Image 4
Quantum LC - 5500 How To Operate, Understanding How Your Unit Works, control panel for light commercial with sensor, Page