Figure 2 - QT3View Screen

QT3View Operation

Part Selector

Tabs

File Open

File Save

Sensor CommPort

Sensor Upload to Adapter

Sensor Download from Adapter

Sensor Upload to Chip

Allows you to view and communicate with the right part. Any serial data transfer will involve only the active tab. The software will auto-recognize the type of chip connected to the QTM300CA and choose the right tab for you.

If no chip is installed, the tab can be manually selected to allow data transfers with the QTM300CA’s onboard e2prom.

Restores a config file saved by (File Save). All three part selector configurations (tabs) will be restored by this action.

Saves all three part selector configurations to disk in a single file, to a file name of your choice.

Selects the desired PC serial port. Com1 is selected by default when the software is first started, if it is available.

Sends the Setups of the open tab to the QTM300CA’s onboard e2prom for use in later cloning. Repeat this step with each selector tab opened in turn, to upload Setups for multiple part types.

Reads the Setups from the e2prom of the QTM300CA into the currently open selector tab. Only the data for the open tab is read. Repeat this step with each tab open in turn to read in all the configurations stored in the QTM300CA.

Sends the Setups from the currently open selector tab directly to the e2prom of a QT3xx chip. Data stored in the QTM300CA is not affected by this opera- tion. The open tab must coincide with the connected chip type.

Sensor Download

Reads the Setups directly from the e2prom of a connected QT3xx chip into the

from Chip

corresponding selector tab. Data stored in the QTM300CA is not affected by

 

 

this operation.

lq

5

QTM300CA/R1.02 25.09.03