QT3View Operation
Part Selector
Tabs
File Open
File Save
Sensor CommPort
Sensor Upload to Adapter
Sensor Download from Adapter
Sensor Upload to Chip
Allows you to view and communicate with the right part. Any serial data transfer will involve only the active tab. The software will
If no chip is installed, the tab can be manually selected to allow data transfers with the QTM300CA’s onboard e2prom.
Restores a config file saved by (File Save). All three part selector configurations (tabs) will be restored by this action.
Saves all three part selector configurations to disk in a single file, to a file name of your choice.
Selects the desired PC serial port. Com1 is selected by default when the software is first started, if it is available.
Sends the Setups of the open tab to the QTM300CA’s onboard e2prom for use in later cloning. Repeat this step with each selector tab opened in turn, to upload Setups for multiple part types.
Reads the Setups from the e2prom of the QTM300CA into the currently open selector tab. Only the data for the open tab is read. Repeat this step with each tab open in turn to read in all the configurations stored in the QTM300CA.
Sends the Setups from the currently open selector tab directly to the e2prom of a QT3xx chip. Data stored in the QTM300CA is not affected by this opera- tion. The open tab must coincide with the connected chip type.
Sensor Download | Reads the Setups directly from the e2prom of a connected QT3xx chip into the |
from Chip | corresponding selector tab. Data stored in the QTM300CA is not affected by |
| |
| this operation. |
lq | 5 | QTM300CA/R1.02 25.09.03 |