Installing ASM-10/8 1
Quick Start Guide
Installation of ASM-10/8 should be carried out only by an experienced
technician. If you are familiar with ASM-10/8, use this quick start guide to
set it up for operation.
Perform the following steps for both the local and the remote units:

QS .1 Installing ASM-10/8

Switch and

Jumper Settings

Set the ASM-10/8 internal jumpers and switches correctly for the chosen
operating mode. Refer to the table below for the possible settings.
Warning
Make sure that the power cord is disconnected before removing the
unit's cover.
Jumper Possible Settings Default Setting
SWITCH EN
DIS
EN
2W/4W 4W
2W
4W
AGC ON
CTRL
ON
CARRIER ON
CTRL
ON
XMT LEVEL 0 dbm
-3 dbm
-6 dbm
-9 dbm
0 dbm
XMT IMPD 600
300
150
LOW
150