RSD-20 OPERATOR'S MANUAL

INSTALLATION

2.5SYSTEM SYNCHRONIZATION AND CLOCK DISTRIBUTION

2.5.1 RSD-20/V.35

Four alternatives are available for synchronization of the system:

a)Main channel modem timing signals.

b)RSD-20 internal clock.

c)Sub-channel 1 modem timing signals.

d)Any sub-channel modem timing signals. For this the optional buffer is required.

2.5.1.1 Synchronization on Main Channel Modem Clock

a)Main channel modem – strapped to internal clock.

b)DCEs attached to sub-channels are strapped to external clock.

c)RSD-20 bit rate setting is ignored (bit rate is determined by main channel modem clock).

 

 

RSD-20

 

 

 

 

SUB DTE

EXT. CLK

DCE

 

 

 

 

 

 

EXT. CK

 

 

 

 

DCE

TX. CLK

MAIN

 

 

 

 

 

INT. CK

 

DTE

 

 

 

 

SUB DCE

TX. CLK

DTE

 

 

 

Figure 2.4

Synchronization on Main Channel Modem’s Clock

2.5

Page 13
Image 13
RAD Data comm System Synchronization and Clock Distribution, RSD-20/V.35, Synchronization on Main Channel Modem Clock