TROUBLESHOOTING GUIDE
PROBLEM: The green Data LED does not light.
SOLUTION: 1) The LED (D1) may be installed backwards.
PROBLEM: The green LED doesn’t flicker off when I aim my remote at it.
SOLUTION: You are trying to relay an IR remote that is modulated at some other frequency than 38 kHz. There is a variety of ranges available, but 38 kHz is by far the most common. Most consumer components operate at 38 kHz. This system ONLY works 38 kHz carrier signal remotes.
PROBLEM: I’m using a radio tuned to 433.42 MHz and I can’t hear the remote control’s signal being
SOLUTION: Check to make sure your radio is set to receive AM signals and that your receiver isn’t so narrow you are missing the signal. Tune around a bit and you will probably find it. If not, it’s possible you made a mistake during as- sembly of the sections surrounding Q1 and Q2. Please check your work and make sure components are mounted flush to the board.
PROBLEM: I just can’t make the darn thing work!
SOLUTION: Call Ramsey Support at
RRW1A SPECIFICATIONS
Power Supply:
•AC supply = 6 to 12 VAC or DC supply = 8 to 16 VDC @ 100 mA (+ tip)
•Current draw with a 12VDC source averages about 20 mA (RRW1A). Dimensions:
•PCB size: 4.0” x 4.7”
•Max component height: 7/8”
Miscellaneous:
•Works with any standard 38 kHz carrier IR remote.
•Max effective BAUD rate: 2400 bps – standard for remotes.
•IR receiver module has an effective
•Max IR LED (D22 of RRW1B) wire extension length: Unknown!! Tested over 750 feet and still going!
RRW1A • 18