Raypak 302BE-902BE warranty Heat Exchanger, Controls, Gas Train, Venting, Construction, Burner

Models: 302BE-902BE

1 2
Download 2 pages 45.96 Kb
Page 1
Image 1
Hi Delta→ - Type H

Job:

 

 

 

 

 

Hi Delta- Type H

Engineer:

 

 

 

 

 

 

 

Hydronic Heating Boiler

 

 

 

 

 

Contractor:

 

 

 

 

 

 

Models 302BE-902BE

Prepared By:

 

Date:

 

 

 

87% Efficiency

 

 

Model:

 

Indoor/Outdoor:

 

 

MBTUH Input:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Š100% Factory Fire Tested

ŠEfficiency: 87%

ŠMaximum Outlet Temperature: 230°FŠMinimum Non-Condensing Inlet Temperature: 120°FŠThermal Shock Proof Heat ExchangerŠLimited Twenty-Year Thermal Shock Warranty

Š Limited Ten-Year Heat Exchanger Warranty Š Diagnostic Center with Fault History

Š PolyTuf Powder Coated CabinetŠ No Combustible Floor Shield RequiredŠFan-Assisted

ŠPatented Burner Security Blanket

Heat Exchanger

ƒH Stamp

ƒHeaders

Engineer: Glass-Lined Cast Iron – Standard

Hydronic Heating Boiler Bronze – Option A-1

ƒASME Inspected and Stamped 160 PSIG Working Pressure

ƒNational Board Approved

ƒFin Tubing

Contractor: Copper – Standard

Models 302BE-902BE Cupro Nickel – Option A-3

ƒASME Steel Tube Sheet

ƒSilicone High Temp O-Rings

ƒPressure Relief Valve, ASME

Prepared By: 45 PSIG – Standard on Models 302BE and 402BE

Date: 60 PSIG – Standard on Models 502BE-902BE

PSIG – Optional

ƒTemperature and Pressure Gauge

ƒWater Connections

87% Efficiency Left – Standard

Model: Right – Option A-6

Controls

ƒ120V, 60Hz, 1Power Supply

ƒ120/24V 60Hz Transformer

ƒ100% Shutoff/Lockout

ƒHot Surface Ignition

ƒRemote Flame Sensor

ƒHigh Limit Control, Manual Reset

ƒOn/Off Power Switch

ƒManual Shut-Off, Front-Mounted

ƒFlow Switch

ƒBlocked Vent Pressure Switch

ƒCombustion Air Proving Switch

ƒEconomaster Pump Time Delay

Gas Train

ƒManual Gas Shut-Off Valve(s)

ƒGas Pressure Regulator

ƒSafety Shut-Off Valve

ƒFiring Control Valve

ƒFiring Mode

Indoor/Outdoor: On/Off (H4): Models 302BE and 402BE

MBTUH Input: 2-Stage (H3): Models 302BE - 902BE

ƒFuel

Š100% Factory Fire Tested Natural Gas

ŠMaximum Outlet Temperature: 230°F Propane Gas

ŠMinimum Non-Condensing Inlet Temperature: 120°F 4” WC Gas Supply Pressure G-20

ƒDesign Certified ANSI Z21.13/ CSA 4.9

Venting

ƒVent Location

ŠThermal Shock Proof Heat Exchanger Top – Standard

ŠLimited Twenty-Year Thermal Shock Warranty Rear – Option D-14

ƒVent Termination Cap

Š PolyTuf Powder Coated Cabinet Outdoor D-11

Š No Combustible Floor Shield Required Indoor, Horizontal D-15

ŠFan-Assisted Indoor, Vertical (by others)

ƒCombustion Air

Heat Exchanger In-Line Filter Kit (Recommended with Ducted-In Air Only) D-17

Controls Air Intake Elbow D-16

ƒExtractor - Optional

Gas Train By Others

Venting Not Required

Construction

ƒIndoor/Outdoor Construction

ƒEnclosed Front Controls

Burner

ƒUltra-Low NOx: Less than 30 PPM

Temperature Controls

 

 

 

 

B-2

Tankstat, Single-Stage (100-200°F)

B-3

Tankstat, 2-Stage (100-200°F)

B-6

Aquastat, 2-Stage (100-200°F)

B-

TempTracker Digital Controller,

 

 

 

2-Stage

 

 

 

 

B-

TempTracker Digital Controller,

 

 

 

4-Stage

 

 

 

 

Y-241

Electronic Sequencer, 4-Stage

Y-281

Electronic Sequencer, 8-Stage

Options

 

 

 

 

 

 

 

C-6

Ignition Module, Manual Reset

D-21

TruSeal® Direct Vent

F-10

Low Water Cut-Off, Remote Probe

I-1

High Limit Control, Auto Reset

P-

 

 

Pump:

 

 

HP, 120V, 1, 60Hz

 

 

 

Water Hardness:

 

 

GPG

 

 

 

Cast Iron

 

 

Bronze

 

 

 

Mounted

 

 

Loose

 

 

 

Front

 

 

Rear

P-26

Cold Water Start (See 2000.48)

S-1

Low Gas Pressure Switch, Manual

S-2

High Gas Pressure Switch,

 

 

 

Manual

 

 

 

 

X-1

SureRack™ Kit

 

 

X-2

SureRack Add-on

 

 

Regulatory Agency Requirements

Catalog No.: 2000.441E

Effective: 11-15-07

Replaces: 1-1-07

Page 1