Raypak 302BE-902BE Rates Of Flow And Pressure Drops, Hi Delta - Type H, Model, Specifications

Models: 302BE-902BE

1 2
Download 2 pages 45.96 Kb
Page 2
Image 2
Hi Delta – Type H

Hi Delta – Type H

Models 302BE-902BE, 87% Efficiency

Model

NOTE: Pump location varies based on model and application

SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

Approx.

 

MBTUH

A

G

H

K

T

W

Amp.

Shipping

Model

Input

Output

Width

NPT

NPT

 

 

 

Draw

Wt. (Lbs)

302BE

300

261

36

3/4

2

5

6

18

6

380

402BE

399

347

43

3/4

2

6

6

18-1/2

6

445

502BE

500

435

50

1-1/4

2

6

6

22

6

545

652BE

650

566

60-1/2

1-1/4

2

8

6

27-1/4

6

590

752BE

750

653

67-1/2

1-1/4

2

8

6

30-3/4

6

675

902BE

900

783

78

1-1/4

2

8

6

36

7

740

Dimensions are in inches.

RATES OF FLOW AND PRESSURE DROPS

Model

10°F ∆T

20°F ∆T

30°F ∆T

 

Min. Flow

 

 

Max. Flow

 

GPM

∆P (ft)

GPM

∆P (ft)

GPM

∆P (ft)

GPM

 

∆P (ft)

∆T

GPM

 

∆P (ft)

∆T

302BE

52

3.4

26

<1

N/A

N/A

20

 

<1

26

90

 

9.8

6

402BE

69

5.8

35

1.5

23

<1

20

 

<1

35

90

 

10.0

8

502BE

87

9.9

44

2.5

29

1.2

22

 

<1

40

90

 

10.5

10

652BE

N/A

N/A

57

4.3

38

2.0

28

 

1.2

40

90

 

10.7

13

752BE

N/A

N/A

65

5.8

44

2.7

33

 

1.7

40

90

 

11.0

15

902BE

N/A

N/A

78

9.0

52

4.1

39

 

2.4

40

90

 

11.8

17

Basis is 20 GPM or 40°F ∆T for minimum flow, 90 GPM for maximum flow.

NOTES: 1. Rates shown are for natural or propane gas, and elevations up to 5,000 feet. For installation above 5,000 feet, please contact manufacturer. 2. Required natural gas pressure is 7 – 10.5” WC. Required propane gas pressure is 11 – 13” WC.

Raypak, Inc. ƒ 2151 Eastman Avenue, Oxnard, CA 93030 ƒ (805) 278-5300 ƒ Fax (800) 872-9725 ƒ www.raypak.com

Catalog No.: 2000.441E

Effective: 11-15-07

Replaces: 1-1-07

Page 2
Image 2
Raypak warranty Rates Of Flow And Pressure Drops, Hi Delta - Type H, Models 302BE-902BE,87% Efficiency, Specifications