2. Product: Delta Limited® copper finned-tube water heater(s)

2.2WATER HEATERS A. General

1. The water heater(s) shall be fired with

 

gas at a rated input of

 

BTU/hr.

2.The water heater(s) shall be CSA tested and certified with a minimum thermal efficiency of 85 percent at full fire.

3.The water heater(s) shall be ASME inspected and stamped and National Board registered for 160 PSIG working pressure, complete with a Manufacturer's Data Report.

4.The water heater(s) shall have a floor loading of 65 lbs. /square foot or less.

B.Heat Exchanger

1.The heat exchanger shall be of a single-bank, horizontal-grid design with eight integral copper fin tubes, each end of which is rolled into an ASME water heater quality steel tube sheet.

2.The heat exchanger shall be sealed to 160 PSIG rated bronze headers with silicone "O" rings, having a temperature rating over 500°F.

3.The low water volume heat exchanger shall be explosion-proof on the water side and shall carry a twenty-year warranty against thermal shock.

4.The headers shall be secured to the tube sheet by stud bolts with flange nuts to permit inspection and maintenance without removal of external piping connections. The heat exchanger shall incorporate "V” baffles between the tubes to ensure complete contact of the external tube surfaces with the products of combustion.

5.The water heater(s) shall be capable of operating at inlet water temperatures as low as 105°F without condensation.

6.The water heater(s) shall be designed to accommodate field changes of either left or right hand plumbing and electrical while leaving the tube bundle in place.

C.Burners

1.The tubular burners shall have multiport radial gas orifices, punched ports and slots, be capable of quiet ignition and extinction without flashback at the orifice, and be manufactured from corrosion-resistant, titanium-stabilized stainless steel with low expansion coefficient.

2.The burners will be supplied with a fan-assisted, clean burning, and highly efficient fuel-air mixture.

D.Pilot Control System

1.The water heater(s) shall be equipped with a 100 percent safety shutdown system.

2.The ignition shall be Hot Surface Ignition type with full flame rectification by remote sensing separate from the ignition source, with a three-try-for-ignition sequence, to ensure consistent operation.

3.The igniter will be located away from the water inlet to protect the device from condensation during startup.

4.The ignition control module shall include an LED that indicates six (6) individual diagnostic flash codes.

5.Two external viewing ports shall be provided, permitting visual observation of burner operation.

E.Gas Train

1.The water heater(s) shall have a firing/leak test valve and pressure test valve as required by CSD-1.

2.The water heater(s) shall have dual-seated main gas valve(s).

3.Gas control trains shall have a redundant safety shut-off feature, main gas regulator, shut-off cock and plugged pressure tapping to meet the requirements of ANSI Z21.10.3/CSA 4.3.

F.Water Heater Control

1.The following safety controls shall be provided:

a.High limit control

b.Flow switch, mounted and wired

c.____PSIG ASME pressure relief valve, piped by the installer to an approved drain

d.Temperature and pressure gauge

Project Name / Date

Division 23 52 33.13 - 2

Page 2
Image 2
Raypak 899B dimensions

899B specifications

The Raypak 899B is a highly efficient and reliable commercial boiler that has gained popularity in various heating applications. This unit is recognized for its robust construction, advanced technologies, and user-friendly features, making it a preferred choice among heating professionals.

One of the main features of the Raypak 899B is its impressive thermal efficiency, which can exceed 90%. This remarkable efficiency translates to lower operating costs and reduced energy consumption, making it an environmentally friendly option for both residential and commercial settings. The boiler is designed to utilize natural gas as fuel, ensuring a cleaner burn and minimal emissions, which is beneficial for users looking to adhere to strict environmental regulations.

The Raypak 899B is equipped with a unique copper fin-tube heat exchanger that enhances heat transfer and maximizes efficiency. This feature allows for quicker heating and improved performance, even in high-demand situations. The heat exchanger is also resistant to corrosion, which contributes to the boiler's longevity and requires less maintenance over time.

User-friendly control systems are another highlight of the Raypak 899B. The boiler incorporates advanced control technologies, allowing users to monitor and adjust settings easily from a central control panel. This includes precise temperature control and diagnostics, which helps ensure optimal operation and simplifies troubleshooting.

Additionally, the Raypak 899B offers flexibility when it comes to installation. With options for direct venting and a compact design, it can fit into various spaces, making it an ideal choice for both new constructions and retrofits. The unit is also designed for both indoor and outdoor installations, providing versatility depending on the project's requirements.

Safety features are paramount in the design of the Raypak 899B. It includes built-in safety controls that help prevent overheating and other potential hazards, ensuring peace of mind for users. Furthermore, the unit complies with various industry standards, highlighting its commitment to safety and quality.

In summary, the Raypak 899B boiler stands out due to its high efficiency, advanced heat exchanger technology, user-friendly controls, installation flexibility, and safety features. These characteristics make it a reliable choice for efficient heating solutions in both commercial and residential applications.