Raypak 962-1826 warranty Raytherm - Type H, Hydronic Heating Boilers, Commercial, Engineer, Date

Models: 962-1826

1 2
Download 2 pages 61.39 Kb
Page 1
Image 1
Raytherm® - Type H

Job:

 

 

 

 

Raytherm® - Type H

Engineer:

 

 

 

 

 

Hydronic Heating Boilers

 

 

 

 

 

Contractor:

 

 

 

 

Commercial

 

 

Date:

Prepared By:

 

Models 962-1826 (Indoor)

Model:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFFICIENT

82% thermal efficiency – highest of any atmospheric boiler available today

THERMAL SHOCK PROOF

Twenty-year warranty against thermal shock damage up to 150°F differential

Maximum operating temperature: 230°F

LIGHTWEIGHT

A floor load of 70 lbs./sq. ft. or less

HIGH RECOVERY

Cuts fuel costs substantially because the standby and radiation losses normal to other boilers are eliminated

LOW WATER OPERATING TEMPERATURE Operates with water temperature as low as 105°F without condensing

INDOOR

Heat Exchanger

ƒASME Inspected and Stamped 160 PSIG

ƒNational Board Approved

ƒHeaders

Engineer: Glass-lined Cast Iron – Standard

Hydronic Heating Boilers Bronze – Option A-1

ƒFinned Tubing

Contractor: Copper – Standard

Commercial Cupro Nickel – Option A-3

ƒASME Steel Tube Sheet

ƒSilicone O-Rings

ƒ60 PSIG ASME Pressure Relief Valve

ƒTemperature and Pressure Gauge

ƒWater Connections

Date: Left Hand – Standard

Prepared By: Right Hand – Option A-6

ƒFlow Configuration

Models 962-1826 (Indoor) Two-pass – Standard

Model: Single-pass – Cast Iron Only

ƒPump - Rear-mounted, 1/2 HP, 120 VAC, 1, 60 Hz – Optional Manual background 4.25” Impeller

Manual background 4.7” Impeller

Controls

ƒ120V, 60Hz, 1 Ph Power Supply

ƒ120/24V Transformer

ƒ100% Pilot Shut-off/Lockout

ƒElectronic, Intermittent Ignition (IID) Pilot

ƒHigh Limit Control, Manual Reset, 240°F

ƒOn/Off Switch

Controls (cont.)

ƒFlow Switch

ƒEconomaster II Pump Time Delay

Gas Train

ƒManual Main Gas Shut-off Cock

ƒMain Gas Pressure Regulator

ƒRedundant Safety Shut-off Valve

ƒControl Valve

ƒFiring Mode

Manual background On/off (H4)

Manual background Two-stage Firing (H3)

Manual background Four-stage Firing (H9)

Manual background Mechanical Modulation, 110-170°F (H5)

Manual background Mechanical Modulation, 150-210°F (H1)

Manual background Motorized Modulation (H2)

Manual background B-6000 (H6)

ƒFuel

Manual background Natural Gas

Manual background Propane Gas

ƒDesign Certified ANSI Z21.13/CSA 4.9

Construction

ƒFront Controls

ƒStainless Steel Burners

ƒPolytuf Powder Coat Finish

ƒVent Selection

Manual background Draft Diverter – Option D-10

Manual background Power Vent, Loose – Option D-2

ƒBase (Optional)

Manual background Combustible Floor Shield – Option J-1

Temperature Controllers

Note: H1 and H5 do not require a controller

B-7

Modulating

B-5

Modulating, Outdoor Reset

B-6

Two-stage

B-

 

 

Four-stage Digital

Y-241

Electronic Sequencer,

 

 

 

1-4 Stages

Y-281

Electronic Sequencer,

 

 

 

1-8 Stages

Additional Safety Controls

Manual backgroundManual background F-9 Low Water Cut-off Probe

Manual backgroundManual background I-1 High Limit Control, Auto

Reset, 240°F

Manual backgroundManual background S-1 Low Gas Pressure Switch,

Manual

Manual backgroundManual background S-2 High Gas Pressure Switch,

Manual

Regulatory Agency Requirements

Catalog No.: 2000.24N

Effective: 12-1-07

Replaces: 10-15-03

Page 1
Image 1
Raypak warranty Raytherm - Type H, Hydronic Heating Boilers, Commercial, Models 962-1826Indoor, Engineer, Contractor