Raypak 962-1826 warranty Raytherm - Type H, Hydronic Heating Boilers, Model, Optional One Pass

Models: 962-1826

1 2
Download 2 pages 61.39 Kb
Page 2
Image 2
Raytherm - Type H

Raytherm - Type H

Hydronic Heating Boilers

Model

 

32 1/2

 

 

K

 

 

OPTIONAL ONE PASS

11 1/4

 

 

H

 

 

 

 

 

15-1/4

 

 

 

7-7/8

 

 

 

 

J

 

 

B

 

 

 

H - OUTLET

OUT

IN

 

 

G

H - INLET

C

 

 

 

 

(OPPOSITE SIDE)

27 3/4

 

GAS

 

 

 

14

 

2 1/2

 

5 1/8

 

 

 

11 1/8

 

6

 

 

 

A

 

19 1/2

A/2

 

 

DRAFT HOOD

 

 

L

(OPTIONAL)

 

 

 

 

 

 

PUMP

 

 

 

(OPTIONAL)

 

 

 

14 1/2

 

 

11 3/4

ELEC.

 

 

 

CONN.

 

 

 

(J-BOX)

 

COMBUSTIBLE FLOOR SHIELD

 

 

1 1/8

(OPTIONAL)

5

 

 

 

MODELS 962 THRU 1826

 

 

 

 

 

Dimensions (Inches)

 

 

 

Approx.

 

MBTUH

 

Overall

Jacket

Gas

Water

 

Flue

 

Shipping

Model

Natural Gas

Width

Height

Height

Conn.

Conns.

 

Dia.

 

Weight

Size

Input

Output

A

B

C

G

H

J

K

L

(Lbs.)

H-962

961.7

788.6

52-3/8

76-1/8 (a)

33-1/2

1

2-1/2 (c)

23-5/8

14

28

705

H-1125

1124.7

922.0

59-1/4

78-1/8 (a)

33-1/2

1 (b)

2-1/2 (c)

23-5/8

16

32

745

H-1223

1222.5

1002.4

63-5/8

78-1/8 (a)

33-1/2

1 (b)

2-1/2 (c)

23-5/8

16

32

805

H-1336

1336.6

1096.0

68-5/8

80-1/8 (a)

33-1/2

1-1/4

2-1/2 (c)

23-5/8

18

36

875

H-1468

1467.0

1203.0

74-7/8

80-1/8 (a)

33-1/2

1-1/4

2-1/2 (c)

23-5/8

18

36

945

H-1631

1630.0

1336.6

81-1/8

83-1/8 (a)

36-1/2

1-1/4

2-1/2 (c)

23-5/8

18

36

985

H-1826

1825.6

1497.0

89-3/8

85-1/8 (a)

36-1/2

1-1/4

2-1/2 (c)

23-5/8

20

40

1035

NOTE: Ratings shown are for elevations up to 2,000 feet. For

(a) Add 1-1/8" to overall height for combustible floor shield option

elevations over 2,000, reduce ratings at the rate of 4% for each

(b) 1" or 1-1/4" contingent on boiler type or code requirements

1,000 feet above sea level.

(c) 3" NPT on single-pass option

BOILER RATE OF FLOW AND PRESSURE DROP

 

 

10° T

 

20° T

 

30° T

 

40° T

TWO PASS

GPM

 

P FT.

GPM

 

P FT.

GPM

 

P FT.

GPM

 

 

P FT.

962

N/A

 

N/A

79

 

8.5

53

 

3.8

N/A

 

 

N/A

1125

N/A

 

N/A

90

 

12.0

61

 

5.5

46

 

 

3.1

1223

N/A

 

N/A

N/A

 

N/A

67

 

7.0

50

 

3.9

1336

N/A

 

N/A

N/A

 

N/A

73

 

8.6

55

 

 

4.9

1468

N/A

 

N/A

N/A

 

N/A

80

 

11.0

60

 

6.2

1631

N/A

 

N/A

N/A

 

N/A

90

 

14.8

67

 

 

8.1

1826

N/A

 

N/A

N/A

 

N/A

N/A

 

N/A

75

 

10.6

ONE PASS

 

 

 

 

 

 

 

 

 

 

 

 

 

962

157

 

6.1

N/A

 

N/A

N/A

 

N/A

N/A

 

 

N/A

1125

184

 

8.8

92

 

2.3

N/A

 

N/A

N/A

 

 

N/A

1223

200

 

11.0

100

 

2.9

N/A

 

N/A

N/A

 

 

N/A

1336

N/A

 

N/A

110

 

3.7

N/A

 

N/A

N/A

 

 

N/A

1468

N/A

 

N/A

120

 

4.5

N/A

 

N/A

N/A

 

 

N/A

1631

N/A

 

N/A

134

 

6.0

N/A

 

N/A

N/A

 

 

N/A

1826

N/A

 

N/A

150

 

8.0

100

 

3.7

N/A

 

 

N/A

N/A: Not Applicable

NOTES: Above values represent maximum flows and pressure drops for closed heating systems.

Maximum acceptable flow through heat exchanger tubes is 90 GPM for two-pass and 200 GPM for single-pass. Single-pass heat exchangers are to be used only when flow rates exceed the allowable for two-pass.

Raypak, Inc. ƒ 2151 Eastman Avenue, Oxnard, CA 93030 ƒ (805) 278-5300 ƒ Fax (800) 872-9725 ƒ www.raypak.com

Catalog No.: 2000.24N

Effective: 12-1-07

Replaces: 10-15-03

Page 2