MVB™ – Type H

Models H7 504-2004

Model

 

 

 

CLEARANCES

 

Certified

Recomm.

 

Minimum

Service

Front

24”

24”

Rear

12”

24”

Right

1”

--

Left

1”

--

Top

0”

10”

Floor

0”

--

Vent

1”

--

PUMP HP – AMPS*

Model

 

Water Hardness

(H7-)

Soft

 

Medium

Hard

504

1/4 - 6

 

1/4 - 6

3/4 - 11

754

1/4 - 6

 

1/2 - 7

3/4 - 11

1104

1/4 - 6

 

1/2 - 7

1 - 14

1504

1/2 - 7

 

1 - 14

1 - 14

2004

1 - 14

 

1-1/2 - 15

1-1/2 - 15

* Current draw is for pump only

Model

MBTUH

 

 

 

 

Dimensions (in.)

 

 

 

 

 

 

Ship

Foot-

Amps*

B

D

E

F

G

H

K

M

N

 

P

R

V

Weight

print

(H7-)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Lbs.)

(Ft2)

 

Input

Output

Height

 

 

 

NPT

NPT

Flue Ø

 

C/A Ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

504

500

420

43

30

35

23-3/4

1

2

8

14-1/8

6

 

36

6

2

600

5.4

12

754

750

630

49

36

41

29-3/4

1

2

10

16

6

 

42

6

2

670

5.4

12

1104

1100

924

55

43

47

35-3/4

1-1/4

2-1/2

10

16

6

 

49

6

2

720

5.4

12

1504

1500

1260

61

50

53

41-3/4

1-1/4

2-1/2

12

18-1/8

8

 

53

6

2

780

5.4

12

2004

1999

1679

75

61

65

53-3/4

2

2-1/2

14

20-1/8

8

 

69

9

5

940

5.4

18

- Ratings shown are for elevations up to 4,500 feet. For installations at elevations

 

 

* Current draw is for heater only.

 

above 4,500 feet, please consult the factory for additional instructions.

 

 

 

 

(Supply breaker must have delayed trip.)

-For direct vent applications, please contact the factory about relocating the pump.

RATES OF FLOW AND PRESSURE DROPS

Model

20°F ∆T

30°F ∆T

40°F ∆T*

Maximum Flow

Minimum Flow*

(H7-)

GPM

∆P (ft.)

GPM

∆P (ft.)

GPM

∆P (ft.)

GPM

∆P (ft.)

∆T (°F)

GPM

∆P (ft.)

∆T (°F)

504

42

2.7

28

1.4

N/A

N/A

100

11.3

8

25

1.1

34

754

63

6.0

42

2.9

32

1.7

100

13.8

13

32

1.7

40

1104

92

13.3

62

6.7

46

4.1

113

18.6

16

46

4.1

40

1504

N/A

N/A

84

13.3

63

8.0

113

22.2

22

63

8.0

40

2004

N/A

N/A

112

26.9

84

16.0

113

27.2

30

84

16.0

40

* Closed systems only

Raypak, Inc. ƒ 2151 Eastman Avenue, Oxnard, CA 93030 ƒ (805) 278-5300 ƒ Fax (800) 872-9725 ƒ www.raypak.com Raypak Canada Ltd. ƒ 2805 Slough St., Mississauga, Ontario, Canada L4T 1G2 ƒ (905) 677-7999 ƒ Fax (905) 677-8036 ƒ www.raypakcanada.com

Catalog No.: 2000.364A

Effective: 8-15-07

Replaces: 6-15-07

Page 2
Image 2
Raypak H7 504-2004 warranty Clearances, Pump HP Amps, Rates of Flow and Pressure Drops