Raytek GP Series

Measurement Specifications (Monitor w/ Sensing Head)

Spectral Response & Temperature Range:

 

Sensing Head Model:

Spectral Response:

Temperature Range:

GPR

8 to 14 microns

-18 to 538°C (0 to 1000°F)

GPM

7.6 to 18 microns

-18 to 538°C (0 to 1000°F)

System Accuracy (mA output)

±1% of measured value or ±1°C (2°F),

 

whichever is greater, @ 23°C ±5°C (73°F ±9°F)

System Repeatability

±0.5% of measured value or ±1°C (2°F) whichever is

 

greater

 

Response Time (95%):

 

 

GPR

700 mSec

 

GPM

1 Sec

 

Emissivity:

0.1 to 1.09 digitally adjustable increments of .01

Signal Processing:

Peak/Valley Hold (up to 998 sec, 999=infinite hold

 

with external reset)

 

 

Variable averaging filter (up to 60 seconds)

 

T-ambient: fixed background ambient temperature

 

compensation

 

Electrical Specifications

Outputs

4-digit, 7 segment LED display, °C/°F selectable

 

User configurable 4-20 mA current or thermocouple

 

output (J,K,E,N,R,S,T)

 

Two adjustable setpoints with deadbands controlling

 

+5 V alarm outputs or optional 3A mechanical relays

Power Supply

110/220 VAC, ±20%, 50-60 Hz

 

User configurable inputs for GPR, GPM, any 0-5 V

 

or 4-20 mA sensor, or thermocouple (J,K,E,N,R,S,T)

 

External Reset input to reset Peak/Valley hold

Sensing Head—Optical Specifications

(NOTE: nominal spot size based on 90% energy)

GPM Sensing Head

Optical Chart

GPR Sensing Head Optical Charts

Dimensions

M 12x1

GPM Sensing Head

Ø 14 (.55)

 

preinstalled cable

17 (.67) 11 (.43)

standard cable length 1 m ( 3 ft.)

28 (1.1)

24 VDC/50 mA excitation voltage

General Specifications

Environmental Rating:

 

 

GP Monitor Front Panel

IP 54

(IEC 529); NEMA-12

GPR Sensing Head

IP 65

(IEC 529); NEMA-4*

GPM Sensing Head

IP 65

(IEC 529); NEMA-4

* GPR rated with adapter and compression fitting

Ambient Temperature Range:

 

 

GP Monitor

0 to 50°C (32 to 120°F)

GPR Sensing Head:

0 to 65°C (32 to 150°F)

With optional water cooling

0 to 177°C (32 to 350°F)

GPM Sensing Head:

0 to 85°C (32 to 185°F)

Ø 5 (0.2)

GPR Sensing Head

Accessories / Options

mm (in)

With optional air cooling

0 to 200°C (32 to 392°F)

Storage Temperature

-30 to 65°C (-22 to 150°F)

Relative Humidity

10 to 95%, non-condensing

GP Monitor Dimensions

1/8 DIN x 120 mm (1.75 x 3.63 x 4.75 in)

GP Monitor Weight

320 g (0.7 lbs)

Cooling housings for high ambient conditions

Air purge fittings for sensing heads

Adjustable mounting brackets and adapters

External isolated solid state relays for alarm outputs (10 Amp AC)

3A mechanical output relays

For Sales and Ordering Contact:

5710 Kenosha Street Richmond, Illinois 60071 USA Phone: +1 (815) 678-2211 FAX: +1 (815) 678-3961 Internet: www.watlow.com e-mail: info@watlow.com

Your Authorized W atlow Distributor Is:

For Service and

W arranty Contact:

Worldwide Headquarters

Raytek Corporation

Santa Cruz, CA USA

Tel: 1 831 458 1110

800 227 8074 (U.S. and Canada only) Fax: 1 831 458 1239 www.raytek.com

Raytek, the Raytek logo, and Thermalert are registered trademarks of Raytek Corporation.

©2001 Raytek Corporation, Printed in USA, 3/01 Rev. A Specifications subject to change without notice. 3-1003

RIC-GP-0401

Page 2
Image 2
RayTek GP Measurement Specifications Monitor w/ Sensing Head, Electrical Specifications, Dimensions, Accessories / Options