9. Maintenance

EBZ5150/RH

9. Maintenance

Maintenance, replacement, or repair of the emission control device and systems may be performed by any non-road engine repair establishment or individual.

 

 

Daily

Every

Every

Every

System/Compornent

Procedure

or

25 hours

50 hours

100 hours

 

 

Before use

after

after

after

Air Filter

Inspect/Clean

 

 

 

Fuel Leaks

Inspect/Replace

 

 

 

Fuel Filter

Inspect/Replace

 

 

Fuel Line

Inspect/Clean

 

 

 

Spark Plug

Inspect/Clean

 

 

 

Muffler

Inspect/Clean

 

 

 

Muffler Spark Arrester

Inspect/Clean

 

 

 

Cooling System

Inspect/Clean

 

 

 

Screws/Nuts/Bolts

Tighten

 

 

 

Cylinder Exhaust Port

Inspect/Clean

 

 

 

U S

Manual backgroundWARNING

Make sure that the engine has stopped and is cool before performing any service to the blower. Contact with rotating blower fan or hot muffler may result in a personal injury.

Do not use mixture gasoline. This type of gasoline does not contain much of oil so that the element becomes dry after a few hours.

(1) 2 Cycle Motor Oil

Manual background NOTE

AIR CLEANER

Never operate the blower without an air

 

filter or with a deformed or broken filter

 

element because unfiltered dusty air

 

will quickly ruin the engine.

Check the air cleaner every 25 hours

Soak the filter element into a 2cycle motor oil. Squeeze the element to remove excess oil so that it weighs 2 to 3 times heavier than that of the dry element.

F18

of use or more frequently if used

under dusty conditions. A clogged

air filter may increase fuel

consumption while cutting down the

engine power. Never operate the

blower without the air filter or with a

deformed filter element because

unfiltered dusty air may quickly ruin

the engine.

F20

 

(3)

 

 

(1)

(4)

(2)

 

 

 

 

 

(5)

3.Place the filter element into the packing. Set the packing into the air cleaner body. Set the cover with 2 fixing screws.

(1)Cover Cleaner

(2)Screen

(3)Cleaner Body

(4)Element

(5)Packing

F19

CLEANING AIR FILTER:

1.Remove the air cleaner cover by pulling the tab on bottom and take out the filter element.

2.Use neutral detergent and warm water to clean the filter element. After cleaning, air dry the element completely and moisten with a small amount of 2 cycle motor oil.

Manual background NOTE

Do not apply 4cycle motor oils as they may damage element.

Manual background NOTE

Assure that the screen is securely fitted to the packing. Fit securely if it is loose.

Insufficient fixing of screws may cause fall off of the cover and insufficient sealing.