Configuration 2: R7r (+CMS) <—ethernet—> R7csi

3 C-LAN Administration

Switch 2 Task — Enable Bus Bridge Connectivity

This task enables the bus bridge functionality on the C-LAN circuit pack to provide a path between the packet bus and the processor.

Note: Bus Bridge Connectivity is used on the csi model only. This task may have been completed when the C-LAN circuit pack was installed.

Steps

 

Begin

 

 

 

 

> Open the Maintenance-Related System Parameters form — enter

ch sys ma

 

> Go to page 2 and skip to the Packet Intf2? field near the bottom of the screen.

 

 

 

 

change system-parameters maintenance

 

Page

2 of 3

 

MAINTENANCE-RELATED SYSTEM PARAMETERS

 

MINIMUM MAINTENANCE THRESHOLDS ( Before Notification )

 

TTRs: 4

CPTRs: 1

Call Classifier Ports: 0

 

MMIs: 0

VCs: 0

 

 

 

TERMINATING TRUNK TRANSMISSION TEST ( Extension )

 

Test Type 100:

Test Type 102:

Test Type 105:

 

ISDN MAINTENANCE

 

 

 

 

ISDN-PRI Test Call Extension:

 

ISDN-BRI Service SPID:

 

DS1 MAINTENANCE

DS0 Loop-Around Test Call Extension:

LOSS PLAN ( Leave Blank if no Extra Loss is Required )

Minimum Number of Parties in a Conference Before Adding Extra Loss:

SPE OPTIONAL BOARDS

 

 

 

 

 

Packet Intf1? y

Packet Intf2? y

 

 

Bus Bridge: 01a05_ Inter-Board Link Timeslots

Pt0: 6 Pt1: 1 Pt2: 1

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

 

 

 

Packet Intf2?

Enables the bus bridge.

 

 

 

 

 

 

 

Bus Bridge:

Location of the C-LAN circuit pack. If the system has two

 

 

 

C-LANs, only one is administered for bus bridge.

 

 

 

 

 

 

Inter-Board

Specifies the bandwidth used on the 3 ports of the Inter-Board

 

 

Link

Link. The total number of timeslots assigned cannot exceed 11.

 

 

Timeslots:

Pt0 carries PPP traffic and can have 1–9 timeslots. Pt1 carries

 

 

Pt0, Pt1, Pt2

maintenance messages and can have 1–3 timeslots. Pt2 carries

 

 

 

broadcast messages and can have 1–3 timeslots.

 

 

 

 

 

 

 

 

> Submit the screen

 

 

 

 

End

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

 

 

555-233-504 — Issue 1 — April 2000

 

CID: 77730

83

Page 103
Image 103
Lucent Technologies Release 8.2 manual Switch 2 Task Enable Bus Bridge Connectivity