Networking Screens

 

 

A Screens Reference

Appl.

Identifies the switch application used on this link.

 

Valid entries

 

Usage

 

 

 

audix, dcs, fp-mwi,gateway,

 

The gateway application is used for conversion

 

gtwy-tcp,mis, msaamwl,

 

between ISDN and either TCP/IP or BX.25.

 

msaclk, msahlwc, msallwc,

 

The gtwy-tcpapplication is used for

 

msamcs, qsig-mwi, and blank

 

conversion between BX.25 and TCP/IP.

 

 

 

These application types are used on the

 

 

 

gateway switch only.

 

 

 

 

Gtwy To

Used for gtwy-tcpapplications only. Identifies the processor channel that this

 

processor channel is serving as a gateway to.

 

 

 

 

 

 

Valid entries

 

Usage

 

1-128(csi model)

 

Two processor channels on the gateway switch are needed

 

 

1-256(si model)

 

to set up a gtwy-tcpgateway, which converts between

 

1-384(r model)

 

X.25 and TCP/IP protocols. For each of the two gtwy-tcp

 

 

 

 

 

processor channels, the Gtwy To field points to the other

 

 

 

 

 

gtwy-tcpprocessor channel.

 

 

 

 

 

For example, if processor channels 5 and 17 are used for a

 

 

 

 

 

gtwy-tcpgateway, Gtwy To for processor channel 5

 

 

 

 

 

would be set to 17 and Gtwy To for processor channel 17

 

 

 

 

 

would be set to 5.

 

 

 

 

 

Mode

Identifies whether the IP session is passive (client) or active (server).

 

Valid

 

Usage

 

 

 

 

 

 

 

entries

 

 

 

 

 

 

c (client)

 

This field must be blank if the type of interface link is x.25 (r model)

 

s (server)

 

or procr-intf (si model). This field cannot be blank if the type of

 

blank

 

interface link is ethernet or ppp.

 

 

 

Set the Mode to s for ppp or ethernet connections to CMS. Set

 

 

 

opposite values (c<-->s) on the endpoints for ppp or ethernet

 

 

 

connections between switches or between a switch and Intuity

 

 

 

AUDIX.

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

274

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 294
Image 294
Lucent Technologies Release 8.2 manual Audix , dcs , fp-mwi , gateway, Gtwy-tcp , mis , msaamwl, Msaclk , msahlwc , msallwc