QSIG

B Private Networking

QSIG Centralized

AUDIX

An analog voice terminal user activates SS-CCBS or SS-CCNR by pressing the Recall button or flashing the switchhook and then dialing the Automatic Callback (ACB) Activation feature access code. An analog user can activate only one ACB call at any given time.

A multiappearance voice terminal user can activate SS-CCBS or SS-CCNR for the number of ACB buttons assigned to the terminal.

SS-CC Options

QSIG SS-CC has the following major options that are negotiated between the Originating and the Terminating PBX:

1Path reservation — there are two methods of establishing the CC call:

a path reservation method b non-reservation method

2Retention of signaling connection — there are two ways in which SS-CC uses call independent signaling connections:

a connection retention method b connection release method

3Service retention — there are two possible behaviors when User B is found to be busy again after User A responds to SS-CC Recall:

aservice retention method

bservice cancellation method

As an originating PBX for QSIG SS-CC, DEFINITY ECS will select the following major options:

non-reservation method for the Path Retention option

connection release method for the Retention of Signaling connection option

service cancellation method for the Service Retention option

As a Terminating PBX for QSIG SS-CC, DEFINITY ECS will select the following major options:

non-reservation method for the Path Retention option

either the connection release method or the connection retention method for the Retention of Signaling connection option depending on which the originating PBX requests.

service cancellation method for the Service Retention option

QSIG allows users on a remote node to “cover” to an AUDIX on another node. The original calling and called party information is provided to AUDIX so that each is identified properly during message recording/retrieval.

To use centralized AUDIX, you must use QSIG Diversion. On a remote switch, the call covers using Diversion to the hunt group assigned to AUDIX on the host switch. Then the host switch sends all the appropriate information to AUDIX so that AUDIX correctly answers the call.

 

 

Administration for Network Connectivity