H.323 Trunk Administration

2 H.323 Trunks

Task 4 — Create a signaling group

This task creates a signaling group that will be associated with H.323 trunks that connect this switch to a far-end switch. One or more unique signaling groups must be established for each far-end node that this switch is connected to via H.323 trunks.

Note: The following steps address only those fields that are specifically related to H.323 trunks. The other fields are administered as for previous releases and are described in the Administrator’s Guide.

Task 4 Steps

Begin

> Open new Signaling Group form — enter a sig n

add signaling-group n

 

 

Page 1 of

5

 

 

SIGNALING GROUP

 

Group Number: 3

 

Group Type: h.323

 

 

 

 

 

 

 

Max number of NCA TSC: 0

 

 

 

 

 

 

 

Max number of CA TSC: 0

 

 

 

 

 

 

 

Trunk Group for NCA TSC:

 

Trunk Group for Channel Selection:

 

 

 

Supplementary Service Protocol: a

 

Near-end Node Name: clan-a1

 

 

Far-end Node Name: clan-b1

 

 

 

 

 

 

 

 

 

Near-end Listen Port: 1720

 

Far-end Listen Port: 1720

 

 

 

 

 

 

LRQ Required? n

Calls Share IP Signaling Connection? n

 

 

 

 

 

 

Bypass If IP Threshold Exceeded? n

 

 

 

 

 

 

Internetworking Message: PROGress

 

 

 

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

 

Group Type:

Enter h.323

 

 

 

 

 

 

Trunk Group for

Leave blank until you create a trunk group in the

 

 

Channel Selection:

following task; then use the change command and enter

 

 

 

 

the trunk group number in this field.

 

 

 

 

 

Near-end Node Name:

Enter the node name for the C-LAN IP interface on this

 

 

 

 

switch. The node name must be administered on the

 

 

 

 

Node Names screen and the IP Interfaces screen.

 

 

 

 

 

Near-end Listen Port:

Enter an unused port number from the range 1719, 1720

 

 

 

 

or 5000–9999. The number 1720 is recommended.

 

 

 

 

Note: If the LRQ field is set to y, the near-end

 

 

 

 

 

 

 

Listen Port must be 1719.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 