Configuration 2: R7r (+CMS) <—ethernet—> R7csi

3 C-LAN Administration

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

Destination Node

Name of the far-end node for this channel. This must be a

 

 

name entered on the Node Names screen.

 

 

 

 

Destination Port

A value of 0 allows any available interface channel on the

 

 

destination node to be used for this connection. The Interface

 

 

Channel number on the Switch-2 Processor Channel screen

 

 

must also be set to 0.

 

 

 

 

 

Session - Local

The Local and Remote Session numbers can be any value

 

 

between 1 and 256 (si model) or 384 (r model), but they must

 

Session - Remote

 

be consistent between endpoints. For each connection, the

 

 

 

 

Local Session number on this switch must equal the Remote

 

 

Session number on the remote switch and vice versa.

 

 

It is allowed, and sometimes convenient, to use the same

 

 

number for the Local and Remote Session numbers. It is

 

 

allowed, but not recommended, to use the same Session

 

 

numbers for two or more connections.

 

 

 

 

 

Mach ID

This field is not used for CMS.

 

 

 

 

 

Processor Channel 12: (ethernet connection to Switch 2)

 

Enable

Set to y.

 

 

 

 

 

 

 

Appl.

Enter dcs for the DCS connection on Processor Channel 12.

 

 

 

 

 

 

Mode

Set the node-5 Mode field to c (“client”) on the Processor

 

 

 

 

Channel Assignment screen on Switch 2.

 

 

 

 

 

 

 

Interface Link

This must match the link number assigned on the node-1 data

 

 

module screen.

 

 

 

 

 

 

 

Interface Chan

For TCP/IP, interface channel numbers are in the range 5000

 

 

– 64500.

 

 

 

 

The recommended values are: 5001 for CMS, 5002 for Intuity

 

 

AUDIX, and 5003 for DCS connections that are not

 

 

 

 

gateways. These three values should be reused for multiple

 

 

 

 

instances of these applications; for example, if there are two

 

 

 

 

Intuity AUDIX’s, use 5002 for both; or if there are four

 

 

 

 

DEFINITY ECS’s, use 5003 for all four. The combination of

 

 

Link, Interface Channel, and Mach ID must be unique.

 

 

 

 

The recommended values for gateway switches is 6001–6099.

 

 

The interface channel number must be unique for each

 

 

 

 

gateway.

 

 

 

 

 

 

 

 

Destination Node

Name of the far-end node for this channel. This must be a

 

 

 

 

name entered on the Node Names screen.

 

 

 

 

 

 

 

 

Destination Port

A value of 0 allows any available interface channel on the

 

 

 

 

destination node to be used for this connection. The Interface

 

 

Channel number on the Switch-2 Processor Channel screen

 

 

 

 

must also be set to 0.

 

 

 

 

 

 

 

2 of 3

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

81

Page 101
Image 101
Lucent Technologies Release 8.2 manual Name entered on the Node Names screen