Lucent Technologies Release 8.2 manual For the call setup. Enter y when administering the data

Models: Release 8.2

1 524
Download 524 pages 28.9 Kb
Page 134
Image 134

Configuration 3: R8si<—x.25 —> R8r Gateway

3 C-LAN Administration

<—ethernet—> R8si

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

 

Enable Link?:

Set to y after the processor channels have been

 

 

 

assigned.

 

 

 

 

 

 

Maintenance Extension:

Specified on dial plan.

 

 

 

 

 

 

Destination Number:

TAC (812) + extension (2102) of the data module on

 

 

 

the far end that will establish the connection.

 

 

 

 

 

 

Establish Connection?

n means that the switch at the remote end of this

 

 

 

connection (Switch 1 in this case) will be responsible

 

 

 

for the call setup. Enter y when administering the data

 

 

 

module for Switch 1.

 

 

 

 

 

 

Connected Data

This is an information-only field.

 

 

Module:

 

 

 

 

 

 

 

Keep the default values for the rest of the fields.

 

 

 

 

 

 

 

2 of 2

 

 

 

 

 

 

 

Administration for Network Connectivity

114

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 134
Image 134
Lucent Technologies Release 8.2 manual For the call setup. Enter y when administering the data