1Administer or check the ISDN Numbering - Public/Unknown screen (see Appendix A).

2Administer or check the ISDN Numbering - Private screen (see Appendix A).

3Administer or check the Signaling Group screen (see Appendix A). Check for the following field entries to ensure proper operation of Call Completion:

Supplementary Service Protocol - b

Max Number of NCA TSC - greater than 0

4Administer or check the Route Pattern screen. Check for the following field entries to ensure proper operation of Call Completion and Transit Counter:

TSC - y (necessary if switch is a transit node for TSC)

Hop Lmt - between 1 and 32

5Administer or check the Feature-Related System Parameters screen. Check for the following field entries to ensure proper operation of Call Completion and Call Transfer:

Trunk-to-Trunk Transfer - y

QSIG TSC Extension - valid extension number to serve as TSC for both incoming and outgoing QSIG network calls.

Automatic Callback - No Answer Timeout Interval (rings) - enter the number of times, 2 to 9, a callback call should ring at the caller’s phone before the callback is cancelled

(For AUDIX/Octel Serenade support only) MWI - Number of Digits per AUDIX Subscriber - enter the number of digits in messaging subscriber extensions, if any. The value in this field must match the value of the Extension Length field on the Switch Interface Administration form of

AUDIX.

(For AUDIX/Octel Serenade support only) Unknown numbers internal for AUDIX - y if, when the switch cannot identify a calling number as internal or external, the switch should treat it as internal for AUDIX use.

6Administer or check the Class of Service (COS) screen for each COS that may be using the QSIG network. Check for the following field entries to ensure proper operation of Call Completion, Call Offer, and Call Forward:

Restrict Call Forward Off-Net - n

Auto Callback- y

QSIG Call Offer Originations - y

 

 