Networking Screens

A Screens Reference

COR

Class of restriction. COR identifies caller and called-party privileges for telephones,

telephone groups, data modules, and trunk groups.

 

Valid

 

Data Module

Usage

 

Entries

 

Types

 

 

 

0-95

 

 

ppp

 

The values for these fields will be specified by

 

Default is 1

 

procr-intf

 

the system administrator.

 

 

x.25

 

 

 

 

 

 

 

Administer the COR so that account codes are

 

 

 

 

pdm

 

 

 

 

 

 

not required. Forced entry of account codes is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

turned off for wideband endpoints.

 

 

 

 

 

 

 

 

TN

Tenant partition number. Enables a single DEFINITY ECS to appear to users as

 

several small independent switches.

 

Valid

 

Data

 

Usage

 

 

 

 

Entries

 

Module

 

 

 

 

 

 

 

Types

 

 

 

 

1-20 (csi,

 

ppp

 

Partitioning could be useful when 2 or more user

 

si)

 

procr-intf

 

groups (tenants) have different switch-usage patterns.

 

1-100 (r)

 

x.25

 

For R6 and later configurations, all MASI trunks are

 

 

pdm

 

 

 

 

 

 

associated with Tenant 1.

 

Default is 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BCC

Bearer capability class. This field is not administrable on the data module screens.

 

BCC is used with ISDN connections to identify the types of traffic that can be

 

supported by a given trunk.

 

 

 

 

 

 

 

Valid

 

Data Module

Usage

 

Values

 

Types

 

 

 

0-4

 

ppp

For non-ISDN connections, leave the default (2).

 

 

 

ethernet

For ISDN connections,

 

 

 

pdm

 

 

 

 

 

 

 

 

 

 

 

0 = Voice only. Use for H.323 trunks.

 

 

 

 

 

 

1 = Mode 1 data — allows restricted

 

 

 

 

 

 

circuit-switched data on a B-channel; 56Kbps

 

 

 

 

 

 

2 = Mode 2 data — 64 Kbps data packaged in an

 

 

 

 

 

 

inverted HDLC protocol and limited to user data

 

 

 

 

 

 

rates between 300bps and 19.2Kbps.

 

 

 

 

 

 

3 = Mode 3 data — when circuit switched, 64Kbps

 

 

 

 

 

 

digital data packaged in LAPD protocol.

 

 

 

 

 

 

4 = Mode 0 data — a data bearer capability that

 

 

 

 

 

 

allows full 64Kbps unrestricted circuit switched data

 

 

 

 

 

 

on a B-channel. Also referred to as clear channel.

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

258

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 278
Image 278