Configuration 3: R8si<—x.25 —> R8r Gateway

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 1 Task — Assign Link via x.25 Data Module to Switch 2

This task administers an x.25 data module for the connection to node 2. The data module associates a link number with a port address and extension number for the PGATE port used for this connection.

Steps

Begin

>If a PGATE circuit pack is not already administered in slot 1c01, insert the circuit pack in the slot and enter add pgate 1c01, then fill in the PGATE screen.

>Open the Data Module form — enter a da n

add data-module next

 

 

 

 

 

Page 1 of 2

 

 

 

DATA MODULE

 

Data Extension: 2102

 

 

Name: x.25 on link 5 to sw-2

Type: x.25

 

COS: 1

Remote Loop-Around Test? n

Port: 01C0102

 

COR: 1

Destination Number: external

Baud Rate: 9600___

 

TN: 1

Establish Connection? y

Endpoint Type: adjunct

DTE/DCE: dte

Connected Data Module: 4121_

Link: 5_

Enable Link? n

Error Logging? n

Permanent Virtual Circuit? y

 

Highest PVC Logical Channel: 64

Switched Virtual Circuit? n

 

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

Type:

 

This indicates the data-module type for this connection.

 

 

 

 

 

Port:

 

This example means that the PGATE circuit pack is in slot

 

 

 

 

01c01 and link 5 uses port 02.

 

 

 

 

 

Baud Rate:

 

Set to 9600 for DCS connections to vs or si models, or to an r

 

 

 

 

model with an external 9600 baud data line.

 

 

 

 

Set to switched for r-to-r connections with common channel

 

 

 

 

signaling on DS1 trunks.

 

 

 

 

Set to 9600 for connections to Intuity AUDIX.

 

 

 

 

Set to either 9600 or 19200 for CMS, depending on the

 

 

 

 

physical connectivity.

 

 

 

 

Endpoint Type:

For DCS, CMS, or Intuity AUDIX, set this field to adjunct.

 

 

 

 

 

Link:

 

The link number must be in the range 1 – 33 (for R8r), not

 

 

 

 

previously assigned on this switch.

 

 

 

 

 

 

 

 

 

 

 

1 of 2

 

 

 

 

 

 

 

 

Administration for Network Connectivity

104

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 124
Image 124
Lucent Technologies Release 8.2 manual Switch 1 Task Assign Link via x.25 Data Module to Switch, Enter values