Networking Screens

A Screens Reference

Data Module - type pdm (used for BX.25 connections with the r model)

This form applies only to the r model.

This form assigns a Modular Processor Data Module (MPDM) data module (700D, 7400B, 7400D or 8400B). The MPDM is an external hardware device that provides a Data Communications Equipment (DCE) interface for connection to equipment such as data terminals, CDR output devices, on-premises administration terminal, Message Server, Property Management System (PMS), AUDIX, and host computers. It also provides a Digital Communications Protocol (DCP) interface to the digital switch.

Use the tdm data module type to assign an MTDM, which provides an EIA Data Terminal Equipment (DTE) interface for connection to off-premises private line trunk facilities or a switched telecommunications network and a DCP interface for connection to the digital switch.

 

 

 

 

Page 1 of 1

 

 

DATA MODULE

 

Data Extension: 30

Name:

27

BCC:

 

Type: pdm_________

COS:

1

Remote Loop-Around Test? n

 

Port: _______

COR:

1

Secondary data module? n

 

ITC: restricted__

TN:

1

Connected to: dte

ABBREVIATED DIALING

 

 

 

List1:

 

 

 

 

SPECIAL DIALING OPTION:

 

 

 

ASSIGNED MEMBER (Station with a data extension button for this data module)

Ext

Name

 

 

 

1: 1002

27 character station name

 

 

 

 

 

 

Common Fields

See Common Data Module Fields (256) for descriptions of fields on this screen that

 

are not listed below.

Secondary data module Specifies whether this PDM is the primary or secondary data module.

Valid Value

Usage

y/n

Enter y if this PDM is the secondary data module used for

 

Dual I-channel AUDIX networking. Enter n if this is the

 

primary PDM, or if this data module is not used for AUDIX

 

networking. The primary data module must be administered

 

before the secondary data module may be added. If Port is

 

X, this field must be set to n.

 

 

 

 

Administration for Network Connectivity

272

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 292
Image 292