Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs)

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 1 Task — Assign Link via ppp Data Module to C-LAN(b)

This task administers a ppp data module on Switch 1 for the ppp connection from the

C-LAN(a) circuit pack to the C-LAN(b) circuit pack.

Steps

Begin

> Open Data Module form — enter ad da 2013

add data-module 2013

 

 

 

 

 

 

 

 

 

 

 

 

Page 1 of x

 

 

 

DATA MODULE

 

 

 

Data Extension: 2013

Name: _ppp on link 12 to clan(b)__ BCC: 2

 

Type: ppp

 

COS: 1

 

 

 

 

 

 

 

 

 

 

 

 

 

Port: 01c0713

 

COR: 1

 

 

 

Link: 12

 

TN: 1

 

 

 

Enable Link? n

 

 

 

 

 

Node Name: node-1a _____

 

 

 

 

 

Subnet Mask: 255.255.255.0

 

 

 

 

 

Establish Connection: y

 

 

 

 

 

 

DESTINATION

 

 

 

 

 

Digits: 2378___________

 

 

 

 

 

Node Name: node-1b___________

 

 

 

CHAP? n

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

 

 

 

 

 

Type:

 

This indicates the data-module type for this link.

 

 

 

 

 

 

 

 

 

 

Port:

 

In this example, the C-LAN(a) circuit pack is in slot

 

 

 

 

 

 

 

 

01a07; the ppp connection is through port 13.

 

 

 

 

 

 

 

 

 

Link:

 

The link number must be in the range 1 – 33 (for R8r), not

 

 

 

 

 

 

 

 

previously assigned on this switch.

 

 

 

 

 

 

 

 

 

Enable Link?

 

If you need to add an IP route that uses this node as a

 

 

 

 

 

 

 

 

gateway, this field must be set to y before adding the IP

 

 

 

 

 

 

 

route. Otherwise leave this field set to n until the link

 

 

 

 

 

 

 

administration is complete; that is, until after all data

 

 

 

 

 

 

 

modules and the processor channels are assigned, then set

 

 

 

 

 

 

 

to y.

 

 

 

 

 

 

 

 

 

 

 

Name:

 

Information-only; appears in list generated by the “list

 

 

 

 

 

 

 

 

data module” command.

 

 

 

 

 

 

 

 

 

 

 

BCC:

 

Bearer Capability Class. This is a display-only field.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

182

 

 

 

 

 

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 202
Image 202