Configuration 5A: R8csi <—ppp—> R8r (one C-LAN)

3 C-LAN Administration

<—ethernet—> R8si

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

Destination Node

Name of the far-end node for this channel. This must be a

 

 

name entered on the Node Names screen. For ppp

 

 

connections, it must match the Destination Node Name

 

 

entered on the ppp Data Module screen.

 

 

 

 

Destination Port

A value of 0 allows any available interface channel on the

 

 

destination node to be used for this connection. The

 

 

Interface Channel number for this connection on the

 

 

Switch-2 Processor Channel screen must also be set to 0.

 

 

 

 

Session - Local

The Local and Remote Session numbers can be any value

 

 

between 1 and 256 (si model) or 384 (r model), but they

 

Session - Remote

 

must be consistent between endpoints. For each connection,

 

 

 

 

the Local Session number on this switch must equal the

 

 

Remote Session number on the remote switch and vice

 

 

versa.

 

 

 

It is allowed, and sometimes convenient, to use the same

 

 

number for the Local and Remote Session numbers. It is

 

 

allowed, but not recommended, to use the same Session

 

 

numbers for two or more connections.

 

 

 

 

Mach ID

Destination switch ID identified on the dial plan of the

 

 

destination switch.

 

 

 

 

 

Processor Channel 13: (ethernet connection to Switch 3)

 

Enable

Set to y.

 

 

 

 

 

 

 

 

Appl.

Set to dcs for DCS signaling.

 

 

 

 

 

 

 

 

Mode

Node-1-eth is the “server” for this session. Set node-3 to

 

 

 

 

“client” ( c).

 

 

 

 

 

 

 

Interface Link

This must match the link number assigned on the node-1b

 

 

data module screen.

 

 

 

 

 

 

 

 

Interface Chan

For TCP/IP, interface channel numbers are in the range

 

 

 

 

5000 – 64500. The value 5003 is recommended for the DCS

 

 

connections. This number must match the Destination Port

 

 

number on the Switch-2 Processor Channel screen. (Note

 

 

 

 

that 5003 can be used for the connections to both Switch 2

 

 

and 3 because they are on different links).

 

 

 

 

 

 

 

Destination Node

Name of the far-end node for this channel. This must be a

 

 

name entered on the Node Names screen. For ppp

 

 

 

 

connections, it must match the Destination Node Name

 

 

 

 

entered on the ppp Data Module screen.

 

 

 

 

 

 

 

Destination Port

A value of 0 allows any available interface channel on the

 

 

destination node to be used for this connection. The

 

 

 

 

Interface Channel number on the Switch-3 Processor

 

 

 

 

Channel screen must also be set to 0.

 

 

 

 

 

 

 

2 of 3

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

155