A Screens Reference

Enable Eth Pt

Used to enable or disable the C-LAN or MedPro IP Ethernet port.

 

Valid Values

 

Usage

 

 

 

y/n

 

The Ethernet port must be enabled (y) before it can be used. The

 

 

 

port must be disabled (n) before changes can be made to its

 

 

 

attributes on this screen.

 

 

 

If an enabled Ethernet port is changed to disabled, all signaling

 

 

 

and/or media connections will be removed and the associated

 

 

 

calls will be torn down.

 

 

 

The busy-outcommand applied to the circuit pack for the

 

 

 

interface overrules the Enable Eth Pt field.

 

 

 

 

Type

Specifies the type of circuit pack for the IP network interface (C-LAN or MedPro).

Slot

Specifies the location of the circuit pack for the IP network interface in the standard

 

CCcss format (CC = cabinet number, c = carrier letter, ss = slot number).

Code

Display only. Specifies the board code of the circuit pack for the IP interface. This

 

field is automatically populated with TN799 for C-LAN or TN802 for MedPro.

Sfx

Display only. Specifies board code suffix. This field is automatically populated with

 

B for the TN802 and the TN799.

Node Name

The unique node name for the IP interface. The node name must be on the Node

 

Names screen (pages 2–6 only; node names on page 1 of the Node Names screen

 

cannot be used in this field).

 

 

Administration for Network Connectivity

248

CID: 77730

555-233-504 — Issue 1 — April 2000