Japan TTC Q931-a Private Networking Protocols

B Private Networking

Setting Up TTC Q931-a

Complete the following steps to set up TTC connections.

Steps

Begin

1Verify that you have the appropriate DEFINITY circuit pack for integration

2Enter “ change system-parameters customer-options on the command line of your system administration screen.

3On page 1, verify that the G3 Version field is V8 or later

4On page 2, verify that ISDN-PRI field is y.

5Administer the TTC DS-1 circuit pack.

Check for the following field entries:

~Connect field — pbx

~Interface — peer-master or peer-slave

~Peer Protocol — TTC

~D-channel: (This item must match between the local and receiving switches)

~Channel Numbering — sequential or timeslot (This item must match between the local and receiving switches)

6Administer or check the TTC ISDN trunk group(s) associated with the DS1 circuit pack.

Check for the following field entries on page 1 of the Trunk Group screen:

~Group type: isdn

~Supplementary Service protocol — a

~Outgoing Display? y

Check for the following field entries On page 2

~Disconnect Supervision — y

~Numbering format — public, private, unknown, unk-pvt

~Send Called/Busy/Connected Number — y

~Sending Calling Number — y

~Send Name — n

End

 

 

Administration for Network Connectivity

402

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 422
Image 422
Lucent Technologies Release 8.2 manual Setting Up TTC Q931-a, ~ Interface peer-master or peer-slave