Other Networking-Related DEFINITY Screens

A Screens Reference

Data Module - type analog-dm

This type of data module behaves identically to a 2500 set, but it accepts rotary dial pulses.

Page 1 of 1

 

DATA MODULE

Data Extension: ____

Name:

Type: analog-dm

COS:

Port: __

COR:

ITC: restricted

TN:

ABBREVIATED DIALING

List1: _______________

SPECIAL DIALING OPTION: ____

HOT LINE DESTINATION

Abbreviated Dialing Dial Code (From above list): _

ASSIGNED MEMBER (Station with a data extension button for this data module)

Ext Name

1.

Common Fields

See Common Data Module Fields (256) for descriptions of fields on this screen that

 

are not listed below.

Abbreviated Dialing

Specifies the type of abbreviated dialing list.

List 1

 

 

 

 

Valid Value

 

Usage

 

s (system)

 

If g or p is entered, a group number or personal list number

 

g (group)

 

also is required. Entry in this field supports Data Hot Line.

 

p (personal)

 

This field can be left blank.

 

e (enhanced)

 

 

 

 

blank

 

 

 

 

 

 

 

 

Special Dialing Option Identifies the type of dialing when this data module originates calls.

 

Valid Value

 

Usage

 

 

 

hot-line,default, or

 

Leave blank for regular (normal) keyboard dialing.

 

 

blank.

 

 

 

 

 

 

 

 

Assigned Member Ext Display only. Extension and name of a previously administered user who has an

 

and Name

associated Data Extension button and who will share the use of the module.

 

 

 

 

 

 

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

297

Page 317
Image 317
Lucent Technologies Release 8.2 manual Data Module type analog-dm, Abbreviated Dialing