Lucent Technologies Release 8.2 manual For this connection. The Destination Port number on

Models: Release 8.2

1 524
Download 524 pages 28.9 Kb
Page 111
Image 111

Configuration 2: R7r (+CMS) <—ethernet—> R7csi

3 C-LAN Administration

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

Destination

Name of the far-end node for this channel. This must be a

 

Node

name entered on the Node Names screen.

 

 

 

 

Destination Port

A value of 0 allows any available interface channel on the

 

 

destination node to be used for this connection. The Interface

 

 

Channel number on the Switch-2 Processor Channel screen

 

 

must also be set to 0.

 

 

 

 

 

Session - Local

The Local and Remote Session numbers can be any value

 

 

between 1 and 256 (si model) or 384 (r model), but they must

 

Session -

 

be consistent between endpoints. For each connection, the

 

Remote

 

Local Session number on this switch must equal the Remote

 

 

 

 

Session number on the remote switch and vice versa.

 

 

It is allowed, and sometimes convenient, to use the same

 

 

number for the Local and Remote Session numbers. It is

 

 

allowed, but not recommended, to use the same Session

 

 

numbers for two or more connections.

 

 

 

 

 

Mach ID

This field is not used for CMS.

 

 

 

 

 

Processor Channel 21: (ethernet connection to Switch 1)

Enable

Set to y.

 

 

Appl.

dcs indicates that this connection will carry DCS data.

 

 

Mode

Node-5 will be the “client” on this session. Set node-1 (on

 

Switch 1) to “server” ( s).

 

 

Interface Link

This must match the link number assigned on the node-5 data

 

module screen.

 

 

Interface Chan

A value of 0 allows any available interface channel to be used

 

for this connection. The Destination Port number on the

 

Switch-1 Processor Channel screen must also be set to 0.

 

 

Destination

Name of the far-end node for this channel. This must be a

Node

name entered on the Node Names screen.

 

 

Destination Port

This number must match the Interface Channel number

 

assigned on the Switch-1 Processor Channel screen.

 

 

 

2 of 3