Configuration 3: R8si<—x.25 —> R8r Gateway

3 C-LAN Administration

<—ethernet—> R8si

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

Destination Port

 

The Destination Port number must match the Interface

 

 

 

Channel number for this connection on the Switch-1

 

 

 

Processor Channel screen.

 

 

 

 

 

Session - Local

 

The Local and Remote Session numbers can be any value

 

 

 

between 1 and 256 (si model) or 384 (r model), but they

 

Session - Remote

 

 

 

must be consistent between endpoints. For each

 

 

 

 

 

 

connection, the Local Session number on this switch must

 

 

 

equal the Remote Session number on the remote switch

 

 

 

and vice versa.

 

 

 

It is allowed, and sometimes convenient, to use the same

 

 

 

number for the Local and Remote Session numbers. It is

 

 

 

allowed, but not recommended, to use the same Session

 

 

 

numbers for two or more connections.

 

 

 

 

 

Mach ID

 

Destination switch ID identified on the dial plan of the

 

 

 

destination switch.

 

 

 

 

Processor Channel 32: (connection to Switch 1 for gateway to Switch 2)

Enable

Set to y.

 

 

Appl.

Set to dcs for DCS signaling.

 

 

Mode

Node-3 is the “client” for this session. Set node-1 to

 

“server” ( s).

 

 

Interface Link

This must match the link number assigned on the node-3

 

data module screen.

 

 

Interface Chan

A value of 0 allows any available interface channel to be

 

used for this connection. This number must match the

 

Destination Port number on the Switch-1 Processor

 

Channel screen.

 

 

Destination Node

Name of the far-end node for this channel. This must be a

 

name entered on the Node Names screen.

 

 

Destination Port

The Destination Port number must match the Interface

 

Channel number for this connection on the Switch-1

 

Processor Channel screen.

 

 

Session - Local

For each connection, the Local Session number on this

 

switch must equal the Remote Session number on the

Session - Remote

remote switch and vice versa.

 

 

 

Mach ID

Destination switch ID identified on the dial plan of the

 

destination switch.

 

 

 

2 of 2

> Submit the screen the screen

End

 

 

Administration for Network Connectivity