Configuration 5A: R8csi <—ppp—> R8r (one C-LAN)

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 1 Task — Assign Link via ppp Data Module to Switch 2

This task administers a ppp data module on Switch 1 for the ppp connection to Switch

2.The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter ad da 2376

add data-module 2376

 

 

 

 

 

 

 

 

 

 

 

Page 1 of x

 

 

 

DATA MODULE

 

 

Data Extension: 2376

 

 

Name: _ppp on link 1 to node-2___

BCC: 2

 

Type: ppp

 

 

COS: 1

 

 

 

 

 

 

 

 

 

 

 

Port: 01c0815

 

 

COR: 1

 

 

Link: 1_

 

 

TN: 1

 

 

Enable Link? n

 

 

 

 

 

Node Name: node-1-ppp

_

 

 

 

Subnet Mask: 255.255.255.0

 

 

Establish Connection: y

 

 

 

 

 

DESTINATION

 

 

 

 

 

Digits: 8993020_________

 

 

Node Name: node-2__________

 

 

CHAP? n

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

 

 

 

 

 

Type:

 

This indicates the data-module type for this connection.

 

 

 

 

 

 

 

 

 

Port:

 

In this example, the C-LAN circuit pack is in slot 01c08; the

 

 

 

 

 

 

ppp connection is through port 15.

 

 

 

 

 

 

 

 

 

 

Link:

 

The link number must be in the range 1 – 33 (for R8r), not

 

 

 

 

 

 

previously assigned on this switch.

 

 

 

 

 

 

 

 

 

 

Enable Link?

 

If you need to add an IP route that uses this node as a gateway,

 

 

 

 

 

 

this field must be set to y before adding the IP route. Otherwise

 

 

 

 

 

 

leave this field set to n until the link administration is complete;

 

 

 

 

 

 

that is, until after all data modules and the processor channels

 

 

 

 

 

 

are assigned, then set to y.

 

 

 

 

 

 

 

 

 

 

Name:

 

Information-only; appears in list generated by the “list data

 

 

 

 

 

 

module” command.

 

 

 

 

 

 

 

 

 

 

BCC:

 

Bearer Capability Class. This is a display-only field.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

 

 

 

555-233-504 — Issue 1 — April 2000

 

 

CID: 77730

149

Page 169
Image 169
Lucent Technologies Release 8.2 manual Digits Node Name node-2 CHAP? n