Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs)

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 1 Task — Assign Link via ethernet Data Module to the LAN

This task administers an ethernet data module on Switch 1 for the ethernet connection. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter a da n

add data next

 

 

 

 

 

Page 1 of X

 

DATA MODULE

 

 

Data Extension: 2377

Name: ethernet on link 2

 

BCC: 2

Type: ethernet

 

 

 

 

Port: 01c0817_

 

 

 

 

Link: 2

 

 

 

 

Network uses 1’s for broadcast addresses? y

 

 

 

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

 

 

Type:

 

This indicates the data-module type for this connection.

 

 

 

 

 

Port:

 

Ethernet connections must be assigned to port 17 on the

 

 

 

C-LAN(b) circuit pack.

 

 

 

 

 

 

 

Link:

 

The link number must be in the range 1 – 33 (for R8r), not

 

 

 

previously assigned on this switch.

 

 

 

 

 

 

 

Name:

 

Information-only; appears in list generated by the “list data

 

 

 

module” command.

 

 

 

 

 

 

 

Network uses

 

Leave the default (y) if the private network contains only

 

1’s for

 

DEFINITY switches and adjuncts. Set to n only if the network

 

broadcast

 

includes non-DEFINITY switches that use the 0’s method of

 

addresses?

 

forming broadcast addresses. See Appendix A, “Data Module -

 

 

 

type ethernet” for more information about this field.

 

 

 

 

 

 

 

 

> Submit the screen

 

 

 

 

 

End

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

179

Page 199
Image 199
Lucent Technologies Release 8.2 manual Open Data Module form enter a da n