Configuration 2: R7r (+CMS) <—ethernet—> R7csi

3 C-LAN Administration

Switch 2 Task— Assign Link via ethernet Data Module to the LAN

This task administers an ethernet data module on Switch 2 for the ethernet connection to Switch 1. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter ad da n

add data next

Page 1 of X

 

 

DATA MODULE

Data Extension:

3201

Name: ethernet on link 5

Type:

ethernet

 

 

Port:

01a0517_

 

 

Link:

5

 

 

Network uses 1’s for broadcast addresses? y

[This data module is assigned the next available extension, 3020.]

> Enter values

Field

 

Conditions/Comments

 

 

 

Type:

 

This indicates the data-module type for this link.

 

 

 

Port:

 

Ethernet connections must be assigned to port 17 on the C-LAN

 

 

circuit pack. In this example, the C-LAN circuit pack is in slot

 

 

1a05.

 

 

 

Link:

 

The link number must be in the range 1 – 25 (R8csi), not

 

 

previously assigned on this switch.

 

 

 

Name:

 

Information-only; appears in list generated by the “list data

 

 

module” command.

 

 

 

Network uses

 

Leave the default (y) if the private network contains only

1’s for

 

DEFINITY switches and adjuncts. Set to n only if the network

broadcast

 

includes non-DEFINITY switches that use the 0’s method of

addresses?

 

forming broadcast addresses. See Appendix A, “Data Module -

 

 

type ethernet” for more information about this field.

 

 

 

> Submit the screen

 

End

 

 

 

 

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

87

Page 107
Image 107
Lucent Technologies Release 8.2 manual Add data next