Other Networking-Related DEFINITY Screens

A Screens Reference

 

Data Module - type netcon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1 of 1

 

 

 

DATA MODULE

 

 

Data Extension: ____

 

Name:

BCC: _

 

Type: netcon

 

 

 

COS: _

Maintenance Extension: ____

 

Physical Channel: __

 

 

COR: _

 

 

Name: ______________

 

 

TN: _

Maximum Bit Rate: ____

 

ITC: restricted

 

 

 

 

 

 

ABBREVIATED DIALING

 

 

 

 

 

List1: _______________

 

 

 

 

 

SPECIAL DIALING OPTION: ____

 

 

 

 

 

HOT LINE DESTINATION

 

 

 

 

 

Abbreviated Dialing Dial Code (From above list): _

 

ASSIGNED MEMBER (Station with a data extension button for this data module)

 

Ext Name

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

Common Fields

See Common Data Module Fields (256) for descriptions of fields on this screen that

 

 

are not listed below.

 

 

 

Physical Channel

Identifies the number of the Network Control/Packet Interface data channel

 

 

(identified as a netcon data channel). This field appears only the si models.

 

 

Valid Value

 

Usage

 

 

 

 

 

 

 

1 to 8

 

 

 

 

 

 

 

 

 

Maintenance Extension The extension used to perform maintenance functions on the standby physical

 

 

channel in a duplicated system. This is the extension specified on the dial plan. The

 

 

standby remote loop around tests fail if this field is not administered.

 

Maximum Bit Rate

Identifies the maximum allowable bit rate for the modem. Displays only if the Modem

 

 

field is y.

 

 

 

 

 

 

Valid entries

 

 

 

Usage

 

 

 

 

 

 

 

300, 1200, 2400,

4800,

 

 

 

9600, 14400, 19200, and

 

 

 

28800

 

 

 

 

 

default is 9600

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

295

Page 315
Image 315
Lucent Technologies Release 8.2 manual Data Module type netcon, Maximum Bit Rate