Configuration 3: R8si<—x.25 —> R8r Gateway

3 C-LAN Administration

<—ethernet—> R8si

 

 

 

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

 

Name:

 

Information-only; appears in list generated by the “list data

 

 

 

module” command.

 

 

 

 

 

 

 

COS:

 

 

 

 

 

 

The values for these fields will be specified by the system

 

COR:

 

 

 

administrator.

 

 

 

 

 

 

TN:

 

 

 

 

 

 

 

 

 

 

 

DTE/DCE:

 

The DTE/DCE assignments must be opposites on the two ends

 

 

 

of the connection. Use dce for node 2.

 

 

 

 

 

Enable Link?

 

Set to y after the processor channels have been assigned.

 

 

 

 

 

 

Remote

 

Set to n unless testing.

 

 

Loop-Around

 

 

 

 

Test?

 

 

 

 

 

 

 

 

Destination

 

external is used when connecting an r-model to an si-model.

 

Number:

 

For an r-to-r connection, enter the TAC+extension.

 

 

 

 

 

Establish

 

y means that this switch will be responsible for the call setup

 

Connection?

 

for this connection. Enter n when administering the data

 

 

 

module for Switch 2.

 

 

 

 

 

 

Connected

 

Extension of node-2 data module.

 

Data Module

 

 

 

 

 

 

 

 

 

Error Logging?

 

Set to n for normal operations.

 

 

 

 

Set to y for testing — logs all data module errors.

 

 

 

 

 

Permanent

 

Always y for DCS, CMS, and Intuity AUDIX.

 

Virtual Circuit?

 

 

 

 

 

 

 

 

Switched

 

Always n for DCS, CMS, and Intuity AUDIX.

 

Virtual Circuit?

 

 

 

 

 

 

 

 

Highest PVC

 

Set to 64 (the default) for normal operations.

 

Logical

 

 

 

 

Channel:

 

 

 

 

 

 

 

 

 

 

 

 

2 of 2

 

 

 

 

 

 

> Submit the screen

 

 

 

End

 

 

 

 

 

 

 