Networking Screens

 

 

 

 

 

A Screens Reference

Data Module - type X.25 (used for BX.25 connections with the r model)

 

 

This form applies only to the r model.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1 of 2

 

 

 

 

DATA MODULE

 

Data Extension: ____

Name: ____________________

 

Type: x.25

 

 

 

 

Remote Loop-Around Test? n

 

Port: __

 

 

COR: 1

 

Destination Number: ______

Baud Rate: __________

 

TN: 1

 

Establish Connection? n

Endpoint Type:_________

 

 

 

 

Connected Data Module: ____

 

Link: 1_

DTE/DCE: ___

Error Logging? _

 

 

 

Enable Link? n

 

 

Permanent Virtual Circuit? _

 

 

 

Highest PVC Logical Channel: __

Switched Virtual Circuit? _

 

 

 

 

 

 

 

 

 

 

 

Common Fields

 

See Common Data Module Fields (256) for descriptions of fields on this screen that

 

 

are not listed below.

 

 

Baud Rate

 

Specifies the data transmission rate for this connection.

 

 

 

Valid entries

 

 

 

Usage

 

 

 

 

 

 

 

 

 

 

 

9600, 19200, switched

 

Set to 9600 for DCS connections to the si model, or to

 

 

 

 

 

 

 

an r model with an external 9600 baud data line.

 

 

 

 

 

 

 

Set to switched for r-to-r connections with

 

 

 

 

 

 

 

common-channel signaling on DS1 trunks.

 

 

 

 

 

 

 

Set to 9600 for connections to Intuity.

 

 

 

 

 

 

 

Set to either 9600 or 19200 for CMS, depending on

 

 

 

 

 

 

 

the physical connectivity.

 

 

 

 

 

 

Endpoint Type

 

Must be assigned as adjunct. An endpoint type is a type of packet switched data

 

 

endpoint that uses X.25 call control procedures. The X.25 Endpoint connects to

 

 

external ports on the PGATE board and to the TDM bus via a DS1 trunk. Ports

 

 

connected to the adjunct endpoint can be either DTEs or DCEs.

 

 

 

Valid entries

 

Usage

 

 

 

 

 

 

 

 

 

 

 

adjunct

 

Set to adjunct for DCS, CMS, or Intuity AUDIX.

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

269

Page 289
Image 289
Lucent Technologies Release 8.2 manual This form applies only to the r model, Set to adjunct for DCS, CMS, or Intuity Audix