Configuration 5A: R8csi <—ppp—> R8r (one C-LAN)

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 3 Task — Assign Link via ethernet Data Module to the LAN

This task administers an ethernet data module on Switch 3 for the ethernet connection. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter a da n

add data next

 

 

Page 1 of X

 

DATA MODULE

 

 

Data Extension: 3901

Name: ethernet on link 1

 

BCC: 2

Type: ethernet

 

 

 

 

Port: 01a0517_

 

 

 

 

Link: 1

 

 

 

 

Network uses 1’s for broadcast addresses? y

 

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

 

Type:

This indicates the data-module type for this link.

 

 

 

 

Port:

Ethernet connections must be assigned to port 17 on the C-LAN

 

 

circuit pack.

 

 

 

 

 

 

Link:

The link number must be in the range 1 – 25, not previously

 

 

assigned on this switch.

 

 

 

 

 

 

Name:

Information-only; appears in “list data module” list.

 

 

 

 

Network

Leave the default (y) if the private network contains only

 

uses 1’s for

DEFINITY switches and adjuncts. Set to n only if the network

 

broadcast

includes non-DEFINITY switches that use the 0’s method of

 

addresses?

forming broadcast addresses. See Appendix A, “Data Module -

 

 

type ethernet” for more information about this field.

 

 

 

 

 

 

> Submit the screen

End

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

167

Page 187
Image 187
Lucent Technologies Release 8.2 manual Open Data Module form enter a da n