Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs)

3 C-LAN Administration

<—ethernet—> R8si

 

 

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

 

 

Session - Local

The Local and Remote Session numbers can be any value

 

 

between 1 and 256 (si model) or 384 (r model), but they

 

Session - Remote

 

must be consistent between endpoints. For each

 

 

 

 

connection, the Local Session number on this switch must

 

 

equal the Remote Session number on the remote switch

 

 

and vice versa.

 

 

 

 

It is allowed, and sometimes convenient, to use the same

 

 

number for the Local and Remote Session numbers. It is

 

 

allowed, but not recommended, to use the same Session

 

 

numbers for two or more connections.

 

 

 

 

 

Mach ID

Destination switch ID identified on the dial plan of the

 

 

destination switch.

 

 

 

 

 

 

 

For Processor Channel 23: (connection to Switch 3 through Switch 1)

 

Enable

Set to y.

 

 

 

 

 

 

Appl.

Set to dcs for DCS signaling.

 

 

 

 

 

Mode

Node-2 is the “client” for this session. Set node-3 to

 

 

“server” ( s).

 

 

 

 

 

Interface Link

This must match the link number assigned on the node-2

 

 

data module screen.

 

 

 

 

 

Interface Chan

A value of 0 allows any available interface channel to be

 

 

used for this connection. The Destination Port number on

 

 

the Switch-3 Processor Channel screen must also be set to

 

 

0.

 

 

 

 

 

 

Destination Node

Name of the far-end node for this channel. This must be a

 

 

name entered on the Node Names screen.

 

 

 

 

 

Destination Port

This number must match the Interface Channel number

 

 

assigned on the Switch-3 Processor Channel screen.

 

 

 

 

 

Session - Local

For each connection, the Local Session number on this

 

 

switch must equal the Remote Session number on the

 

Session - Remote

 

remote switch and vice versa.

 

 

 

 

 

 

 

Mach ID

Destination switch ID identified on the dial plan of the

 

 

destination switch.

 

 

 

 

 

2 of 2

 

 

 

 

 

> Submit the screen

 

 

End

 

 

 

 

 

 

 

 

Administration for Network Connectivity

194

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 214
Image 214
Lucent Technologies Release 8.2 manual 194 CID