Other Networking-Related DEFINITY Screens

A Screens Reference

Synchronization Plan

This screen assigns primary and secondary external synchronization sources. This provides synchronization between the switch and digital facilities that the switch is connected to. When the switch is connected to digital facilities, the switch (both Processor Cabinets and Expansion Cabinets) must be synchronized to the incoming data rate of 8,000 frames-per-second. This timing information reference may be derived from DS1 facilities or from a Stratum 3 external clock. Loss of the reference signal, excessive phase changes, and variation in timing frequency can cause loss of data or dropped data connections. When no external digital facilities, including Stratum 3 external clocks, are present or when a switch is the "master" node of a network providing timing to the rest of the network, the timing can come from an oscillator on the switch’s tone/clock circuit pack.

The Synchronization Plan may not be required for some digital connections. The switch’s internal clock may suffice.

Page 1 of the screen

 

 

 

 

 

 

Page 1 of X

 

 

 

SYNCHRONIZATION PLAN

 

 

 

 

SYNCHRONIZATION SOURCE (circuit

pack location)

 

 

 

Stratum: _

 

 

 

 

 

 

 

Port Network: _

 

 

 

 

 

 

 

Primary: ___

Secondary: ___

 

 

Location Name

Slip

Type

Location

Name

Slip

Type

01C17

______________

D

UDS1-BD

_____

_______________

_

___

01C18

______________

Y

TBRI-BD

_____

_______________

_

___

_____

_______________

_

 

_____

_______________

_

___

_____

_______________

_

 

_____

_______________

_

___

_____

_______________

_

 

_____

_______________

_

___

_____

_______________

_

 

_____

_______________

_

___

_____

_______________

_

 

_____

_______________

_

___

_____

_______________

_

 

_____

_______________

_

___

NOTE: TN722B

& TN464B DS1 sources result in

stratum 4, type II synchronization

 

 

 

 

 

 

 

 

 

Stratum

Enter the stratum level to be used for synchronization.

 

 

Valid entries

 

Usage

 

 

 

 

 

3, 4

 

Stratum 3 capability is only possible when

 

 

 

 

using a TN780 Tone Clock circuit pack.

 

 

 

 

 

 

Port Network

Only displays when the Stratum field is 3.

 

 

 

 

 

 

 

Valid entries

 

Usage

 

 

Display-only field.

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

304

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 324
Image 324
Lucent Technologies Release 8.2 manual of the screen, Stratum, Port Network