Networking Screens

 

A Screens Reference

Type H.323

The H.323 signaling group type is used for H.323 trunks.

 

 

 

 

 

 

 

Page 1 of 5

 

 

SIGNALING GROUP

Group Number: 2

Group Type: h.323

 

 

 

Max number of NCA TSC: 0

 

 

 

Max number of CA TSC: 0

 

 

 

Trunk Group for NCA TSC:

Trunk Group for Channel Selection:

 

 

Supplementary Service Protocol: a

 

Near-end Node Name:

 

Far-end Node Name:

Near-end Listen Port: 1720

Far-end Listen Port:

 

LRQ Required? n

 

Calls Share IP Signaling Connection? n

 

 

 

Bypass If IP Threshold Exceeded? n

 

 

 

Internetworking Message: PROGress

 

 

 

 

Near-end Node Name

 

 

 

 

 

.

 

 

 

 

 

Valid entries

 

 

 

Usage

 

 

 

 

 

A node name administered on

Enter the node name for the C-LAN IP interface

 

the Node Names form on this

on this switch.

 

switch.

 

 

 

 

 

 

 

 

 

 

 

Far-end Node Name

 

 

 

 

 

.

 

 

 

 

 

Valid entries

 

 

 

Usage

 

 

 

 

 

A node name administered on

 

Optional. If entered, this is the node name for the

 

the Node Names form on this

 

far-end C-LAN IP Interface used for trunks

 

switch.

 

 

 

assigned to this signaling group.

 

 

 

 

 

 

 

Near-end Listen Port

 

 

 

 

 

.

 

 

 

 

 

Valid entries

 

Usage

 

 

 

1719, 1720 or

 

Enter an unused port number. The number 1720 is

 

5000–9999

 

recommended.

 

 

 

If LRQ is set to y, this field must be 1719.

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

287

Page 307
Image 307
Lucent Technologies Release 8.2 H.323 signaling group type is used for H.323 trunks, Valid entries Usage 1719, 1720 or