Configuration 4: R8csi <—ISDN—> R8si Gateway

3 C-LAN Administration

<—ppp—> R8csi

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

Session - Local

The Local and Remote Session numbers can be any value

 

 

between 1 and 256 (si model) or 384 (r model), but they must

 

Session -

 

be consistent between endpoints. For each connection, the

 

Remote

 

Local Session number on this switch must equal the Remote

 

 

 

 

Session number on the remote switch and vice versa.

 

 

It is allowed, and sometimes convenient, to use the same

 

 

number for the Local and Remote Session numbers. It is

 

 

allowed, but not recommended, to use the same Session

 

 

numbers for two or more connections.

 

 

 

 

Mach ID

Destination switch ID identified on the dial plan of the

 

 

destination switch.

 

 

 

 

 

Processor Channel 32: (connection to Switch 1 for gateway to Switch 2)

Enable

Set to y.

 

 

 

 

Appl.:

Set to dcs for DCS signaling.

 

 

 

Mode

Node-3 is the “client” for this session. Set node-1 to “server”

 

(s).

 

 

 

Interface Link

This must match the link number assigned on the data module

 

screen.

 

 

 

Interface Chan

A value of 0 allows any available interface channel to be used

 

for this connection. This number must match the Destination

 

Port number on the Switch-1 Processor Channel screen.

 

 

 

Destination

Node name for the gateway through which the destination is

Node

reached. This must be a name entered on the Node Names

 

screen. For ppp connections, it must match the Destination

 

Node Name entered on the ppp Data Module screen.

 

 

 

Destination Port

This must match the Interface Channel number assigned on

 

the Switch-1 Processor Channel screen.

 

 

 

Session - Local

For each connection, the Local Session number on this switch

 

Session -

must equal the Remote Session number on the remote switch

and vice versa.

Remote

 

 

 

 

 

Mach ID

Destination switch ID identified on the dial plan of the

 

destination switch.

 

 

 

2 of 2

 

 

 

 

> Submit the screen

 

 

End

 

 

 

 

 

 

 

Administration for Network Connectivity