Lucent Technologies Release 8.2 manual Extension in the dial plan Enter values

Models: Release 8.2

1 524
Download 524 pages 28.9 Kb
Page 147
Image 147

Configuration 4: R8csi <—ISDN—> R8si Gateway

3 C-LAN Administration

<—ppp—> R8csi

 

Switch 1 Task — Assign Link via ppp Data Module to Switch 3

This task administers a ppp data module for the ppp connection to node 3. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter ad da 5803

add data-module 5803

Page 1 of x

 

DATA MODULE

 

 

Data Extension: 5803

 

 

 

Name: _ppp on link 1 to node-3___

BCC: 2

Type: ppp

 

 

 

COS: 1

 

 

 

 

 

 

 

 

 

 

 

Port: 01b1115

 

 

 

COR: 1

 

 

Link: 1_

 

 

 

TN: 1

 

 

Enable Link? n

 

 

 

 

 

 

Node Name: node-1

_____

 

 

 

 

 

 

 

 

 

 

Subnet Mask: 255.255.255.0

 

 

Establish Connection: y

 

 

 

 

 

 

DESTINATION

 

 

 

 

 

 

Digits: 792801_________

 

 

Node Name: node-3_________

 

 

CHAP? n

 

 

 

 

 

 

 

 

 

 

[This data module is assigned the extension 5803; you can assign any unused

extension in the dial plan]

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

 

 

Conditions/Comments

 

 

 

 

 

 

 

 

 

Type:

 

 

This indicates the data-module type for this connection.

 

 

 

 

 

 

 

 

Port:

 

 

In this example, the C-LAN circuit pack is in slot 01b11; the ppp

 

 

 

 

 

 

connection is through port 15.

 

 

 

 

 

 

 

 

 

Link:

 

 

The link number must be in the range 1 – 25 (for R8si), not

 

 

 

 

 

 

previously assigned on this switch.

 

 

 

 

 

 

 

 

 

Enable

 

 

If you need to add an IP route that uses this node as a gateway,

 

 

Link?

 

 

this field must be set to y before adding the IP route. Otherwise

 

 

 

 

 

 

leave this field set to n until the link administration is complete;

 

 

 

 

 

 

that is, until after all data modules and the processor channels are

 

 

 

 

 

 

assigned, then set to y.

 

 

 

 

 

 

 

 

 

Name:

 

 

Information-only; appears in list generated by the “list data

 

 

 

 

 

 

module” command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

 

 

 

 

555-233-504 — Issue 1 — April 2000

 

 

 

CID: 77730

127

Page 147
Image 147
Lucent Technologies Release 8.2 manual Extension in the dial plan Enter values