Networking Screens

 

A Screens Reference

 

 

Far-end Listen Port

 

 

 

.

 

 

 

 

Valid entries

 

Usage

 

 

 

 

 

blank or

 

Optional. If entered, the same number as entered in

 

 

0–65535

 

the Near-end Listen Port field is recommended; if not

 

 

 

left blank, this number must match the number

 

 

 

 

 

 

 

 

entered in the Near-end Listen Port field on the

 

 

 

 

signaling group form for the far-end switch.

 

 

 

 

 

 

 

IRQ Required?

 

 

 

.

 

 

 

 

Valid entries

 

Usage

 

 

 

 

 

y

 

Leave the default (n) if the far-end switch is a

 

 

n (default)

 

DEFINITY ECS. Set to y only if the far-end switch is

 

 

 

a non-DEFINITY switch and requires a location

 

 

 

 

 

 

 

 

request (to obtain a signaling address) in its signaling

 

 

 

 

protocol.

 

 

 

 

 

 

Calls Share IP signaling connection?

 

.

 

 

 

 

Valid entries

 

Usage

 

 

 

 

 

y

 

Enter y for inter-DEFINITY connections. Otherwise,

 

 

n (default)

 

leave the default (n).

 

 

 

 

 

 

 

 

 

 

Bypass if IP Threshold Exceeded?

 

.

 

 

 

 

Valid entries

 

Usage

 

 

 

 

 

y

 

Set to y to automatically remove from service trunks

 

 

n (default)

 

assigned to this signaling group when IP transport

 

 

 

performance falls below limits administered on the

 

 

 

 

 

 

 

 

Maintenance-Related System Parameters (sys par

 

 

 

 

maint) screen.

 

 

 

 

 

 

Internetworking Message

Specifies whether the system sends alerting or progress if an incoming trunk call is routed to a non-ISDN trunk group (for example, CO or tie). This field is administerable on a per-port basis.

.

Valid entries

Usage

PROGress (default)

ALERTing

 

 

Administration for Network Connectivity

288

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 308
Image 308
Lucent Technologies Release 8.2 manual 65535