Configuration 3: R8si<—x.25 —> R8r Gateway

3 C-LAN Administration

<—ethernet—> R8si

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

Session - Local

The Local and Remote Session numbers can be any value

 

 

between 1 and 256 (si model) or 384 (r model), but they must

 

Session - Remote

 

be consistent between endpoints. For each connection, the

 

 

 

 

Local Session number on this switch must equal the Remote

 

 

Session number on the remote switch and vice versa.

 

 

It is allowed, and sometimes convenient, to use the same

 

 

number for the Local and Remote Session numbers. It is

 

 

allowed, but not recommended, to use the same Session

 

 

numbers for two or more connections.

 

 

 

 

Mach ID

Destination switch ID identified on the dial plan of the

 

 

destination switch.

 

 

 

 

 

Processor Channel 23: (The X.25 side of the gateway)

Enable

Set to y.

 

 

 

 

Appl.

Use gtwy-tcpfor conversion between X.25 and TCP/IP.

 

 

 

 

Gateway To

Indicates a software connection between processor channels

 

 

23 and 32.

 

 

 

 

Mode

Used for TCP/IP connections only.

 

 

 

 

Interface Link

This must match the link number assigned on the x.25 data

 

 

module screen.

 

 

 

 

Interface Chan

The interface channel number must be in the range 1 – 64 for

 

 

an X.25 link.

 

 

 

 

Destination Node

Used for TCP/IP connections only.

 

 

 

 

Destination Port

Used for TCP/IP connections only.

 

 

 

 

Session - Local

For each connection, the Local Session number on this switch

 

 

must equal the Remote Session number on the remote switch

 

Session - Remote

 

and vice versa.

 

 

 

 

 

 

Mach ID

Leave blank for gtwy-tcp.

 

 

 

 

Processor Channel 31: (ethernet connection to Switch 3)

 

Enable

Set to y.

 

 

 

 

Appl.

Set to dcs for DCS signaling.

 

 

 

 

Mode

Node-1 is the “server” for this session. Set node-3 to “client”

 

 

(c).

 

 

 

 

Interface Link

This must match the link number assigned on the node-1 data

 

 

module screen.

 

 

 

 

 

2 of 4

 

 

 

Administration for Network Connectivity

110

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 130