Configuration 2: R7r (+CMS) <—ethernet—> R7csi

3 C-LAN Administration

Switch 1 Task — Assign Link via ethernet Data Module to the LAN

This task administers an ethernet data module for the ethernet connection to the CMS adjunct and to Switch 2. The data module defines a network interface — it associates a link number with a port address and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter a da n

add data-module next

Page 1 of X

 

 

DATA MODULE

Data Extension: 2377

Name: ethernet on link 2

Type: ethernet

 

 

 

Port: 01c0817_

 

 

 

Link: 2

 

 

 

Network uses 1’s for broadcast addresses? y

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

Type:

This indicates the data-module type for this link.

 

 

 

 

Port:

Ethernet connections must be assigned to port 17 on the C-LAN

 

 

circuit pack.

 

 

 

 

Link:

The link number must be in the range 1 – 33 (for G3r), not

 

 

previously assigned on this switch.

 

 

 

 

Name:

This field is information-only; it appears in lists generated by the

 

 

“list data module” command.

 

 

 

 

Network

Leave the default (y) if the private network contains only

 

uses 1’s for

DEFINITY switches and adjuncts. Set to n only if the network

 

broadcast

includes non-DEFINITY switches that use the 0’s method of

 

addresses?

forming broadcast addresses. See Appendix A, “Data Module -

 

 

type ethernet” for more information about this field.

 

 

 

 

 

> Submit the screen

End

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730