Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs)

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 3 Task — Assign Link via ethernet Data Module to the LAN

This task administers an ethernet data module on Switch 3 for the ethernet connection to Switch 1. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter a da n

add data next

 

 

 

 

 

 

Page 1 of X

 

 

DATA MODULE

 

 

 

Data Extension: 3901

Name: ethernet on link 1

 

BCC: 2

Type: ethernet

 

 

 

 

 

 

Port: 01a0517_

 

 

 

 

 

 

Link: 1

 

 

 

 

 

 

Network uses 1’s for broadcast addresses? y

 

 

 

 

 

 

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

 

 

 

 

 

 

Type:

 

This indicates the data-module type for this connection.

 

 

 

 

 

 

 

 

 

Port:

 

Ethernet connections must be assigned to port 17 on the

 

 

 

 

 

C-LAN circuit pack.

 

 

 

 

 

 

 

 

 

 

 

Link:

 

The link number must be in the range 1 – 25 (for R8si), not

 

 

 

 

 

previously assigned on this switch.

 

 

 

 

 

 

 

 

 

 

 

Name:

 

Information-only; appears in list generated by the "list data

 

 

 

 

 

module" command.

 

 

 

 

 

 

 

 

 

 

 

Network uses 1’s

 

Leave the default (y) if the private network contains only

 

 

 

for broadcast

 

DEFINITY switches and adjuncts. Set to n only if the

 

 

 

addresses?

 

network includes non-DEFINITY switches that use the 0’s

 

 

 

 

 

method of forming broadcast addresses. See Appendix A,

 

 

 

 

 

“Data Module - type ethernet” for more information about

 

 

 

 

 

this field.

 

 

 

 

 

 

 

 

 

 

 

 

 

> Submit the screen

 

 

 

 

 

 

 

End

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730